Q-Cells Q.TRON S-G3R.12+ / BFG 440 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660
VS
The verdict
TRON S-G3R.12+ / BFG 440 leads on the differences that matter
The largest is module efficiency: 0.80 pp more efficient. 3 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 15 differencesHow alike are they
3
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 18 parameters
What actually differs
Parameter
TRON S-G3R.12+ / BFG 440
PEAK DUO ML-G12S.3 / BFG 660
Difference
Module efficiency
22.00 %
21.20 %
0.80 pp more efficient
Temperature coefficient
-0.300 %/°C
-0.340 %/°C
0.040 %/°C better in heat
Rated power
440 Wp
660 Wp
220 W more power
Weight
20.9 kg
38.2 kg
17.3 kg lighter
Weight per kWp
47.5 kg/kWp
57.9 kg/kWp
10.4 kg/kWp lighter
Product warranty
25 yrs
12 yrs
13 yrs longer
Power density
220.2 Wp/m²
212.5 Wp/m²
7.7 Wp/m² higher
Annual degradation
0.33 %/yr
0.45 %/yr
0.12 %/yr slower
Open-circuit voltage
34.67 V
45.68 V
11.01 V apart
Short-circuit current
15.95 A
18.36 A
2.41 A apart
Module area
1.998 m²
3.106 m²
1.108 m² apart
Voltage at max power
29.72 V
37.94 V
8.22 V apart
Current at max power
14.81 A
17.39 A
2.58 A apart
Cell count
96
132
36 cells apart
Dimensions
1762x1134x30 mm
2384x1303x35 mm
1762x1134x30 mm vs 2384x1303x35 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
TRON S-G3R.12+ / BFG 440
14,844 kWh
PEAK DUO ML-G12S.3 / BFG 660
21,734 kWh
Lifetime gap
6,890 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
TRON S-G3R.12+ / BFG 440
PEAK DUO ML-G12S.3 / BFG 660
Standard test conditions
25 °C
100.0% of rated power
440 W
660 W
Cool, bright day
40 °C
94.9% of rated power
420 W
626 W
Typical summer roof
55 °C
89.8% of rated power
400 W
593 W
Hot roof
70 °C
84.7% of rated power
381 W
559 W
03
Full specification
Parameter
TRON S-G3R.12+ / BFG 440
PEAK DUO ML-G12S.3 / BFG 660
Difference
Power and efficiency
Rated power
440 Wp
660 Wp
+220 W for PEAK DUO ML-G12S.3 / BFG 660
Module efficiency
22.00 %
21.20 %
+0.80 pp for TRON S-G3R.12+ / BFG 440
Power density
220.2 Wp/m²
212.5 Wp/m²
+7.7 Wp/m² for TRON S-G3R.12+ / BFG 440
Open-circuit voltage
34.67 V
45.68 V
11.01 V apart
Voltage at max power
29.72 V
37.94 V
8.22 V apart
Short-circuit current
15.95 A
18.36 A
2.41 A apart
Current at max power
14.81 A
17.39 A
2.58 A apart
Temperature
Temperature coefficient
-0.300 %/°C
-0.340 %/°C
+0.040 %/°C for TRON S-G3R.12+ / BFG 440
Mechanical
Dimensions
1762x1134x30 mm
2384x1303x35 mm
1762x1134x30 mm vs 2384x1303x35 mm
Module area
1.998 m²
3.106 m²
1.108 m² apart
Weight
20.9 kg
38.2 kg
-17.3 kg for TRON S-G3R.12+ / BFG 440
Weight per kWp
47.5 kg/kWp
57.9 kg/kWp
-10.4 kg/kWp for TRON S-G3R.12+ / BFG 440
Warranty and degradation
Product warranty
25 yrs
12 yrs
+13 yrs for TRON S-G3R.12+ / BFG 440
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.33 %/yr
0.45 %/yr
-0.12 %/yr for TRON S-G3R.12+ / BFG 440
Technology
Cell technology
TOPCon
-
Not published by Q-Cells
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
96
132
36 cells apart
Bifacial
Yes
Yes
Same
04
14,129 panels
Against the whole database
Efficiency
#6,580
vs
#9,145
TRON S-G3R.12+ / BFG 440 leads by 2,565 places
Power density
#6,391
vs
#9,028
TRON S-G3R.12+ / BFG 440 leads by 2,637 places
Heat behaviour
#6,152
vs
#8,846
TRON S-G3R.12+ / BFG 440 leads by 2,694 places
Weight
#1,726
vs
#11,554
TRON S-G3R.12+ / BFG 440 leads by 9,828 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#7,117
vs
#3,269
PEAK DUO ML-G12S.3 / BFG 660 leads by 3,848 places
05
Open the full database
More useful comparisons
Same series, other bin
Q-Cells Q.TRON S-G3R.12+ / BFG 440 vs Q-Cells Q.TRON S-G3R.12+ / BFG 450
3 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.TRON S-G3R.12+ / BFG 440 vs Q-Cells Q.TRON S-G3R.12+ / BFG 445
One difference: module efficiency
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 675
3 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 670
3 differences, the largest is module efficiency
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 665
One difference: module efficiency
Same series, other bin
Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 655
The same specification on paper
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Q-Cells Q.TRON S-G3R.12+ / BFG 440 or Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660?
According to our database: Q-Cells Q.TRON S-G3R.12+ / BFG 440 has higher module efficiency (22.00% vs 21.20%); Q-Cells Q.TRON S-G3R.12+ / BFG 440 tolerates heat better (temp coeff -0.300%/°C vs -0.340%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Q-Cells Q.TRON S-G3R.12+ / BFG 440 and Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660?
Q-Cells Q.TRON S-G3R.12+ / BFG 440 has a module efficiency of 22.00%, while Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 is 21.20%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Q-Cells Q.TRON S-G3R.12+ / BFG 440 use vs Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660?
Q-Cells Q.TRON S-G3R.12+ / BFG 440 uses TOPCon cells; Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 uses Monocrystalline. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Q-Cells Q.TRON S-G3R.12+ / BFG 440 and Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660?
Q-Cells Q.TRON S-G3R.12+ / BFG 440 has a 30 years power warranty; Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Q-Cells Q.TRON S-G3R.12+ / BFG 440 and Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 bifacial panels?
Both Q-Cells Q.TRON S-G3R.12+ / BFG 440 and Q-Cells Q.PEAK DUO ML-G12S.3 / BFG 660 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 18 Q-Cells offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.