Skip to main content
590 TB M10_1A vs 132-610-THGB-G12R 6 of 19 identical Swap Change panels

Premier Energies PE-590 TB M10_1A vs Premier Energies PE-132-610-THGB-G12R

Premier Energies PE-590 TB M10_1A
Premier Energies
PE-590 TB M10_1A
590 Wp 22.83 % TOPCon Bifacial
VS
Premier Energies
PE-132-610-THGB-G12R
610 Wp 22.58 % N-type Bifacial
The verdict

590 TB M10_1A leads on the differences that matter

The largest is weight: 5.5 kg lighter. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter 590 TB M10_1A 132-610-THGB-G12R Difference
Weight 28.0 kg 33.5 kg 5.5 kg lighter
Weight per kWp 47.5 kg/kWp 54.9 kg/kWp 7.5 kg/kWp lighter
Rated power 590 Wp 610 Wp 20 W more power
Module area 2.583 m² 2.701 m² 0.118 m² apart
Short-circuit current 14.04 A 15.62 A 1.58 A apart
Module efficiency 22.83 % 22.58 % 0.25 pp more efficient
Temperature coefficient -0.300 %/°C -0.290 %/°C 0.010 %/°C better in heat
Cell technology TOPCon N-type TOPCon vs N-type
Open-circuit voltage 51.42 V 49.06 V 2.36 V apart
Cell count 144 132 12 cells apart
Voltage at max power 44.15 V 41.39 V 2.76 V apart
Current at max power 13.37 A 14.74 A 1.37 A apart
Dimensions 2278x1134x35 mm 2382x1134x35 mm 2278x1134x35 mm vs 2382x1134x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
590 TB M10_1A
19,796 kWh
132-610-THGB-G12R
20,467 kWh
Lifetime gap
671 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 590 TB M10_1A 132-610-THGB-G12R
Standard test conditions 25 °C 100.0% of rated power 590 W 610 W
Cool, bright day 40 °C 95.5% of rated power 563 W 583 W
Typical summer roof 55 °C 91.0% of rated power 537 W 557 W
Hot roof 70 °C 86.5% of rated power 510 W 530 W
03

Full specification

Parameter 590 TB M10_1A 132-610-THGB-G12R Difference
Power and efficiency
Rated power 590 Wp 610 Wp +20 W for 132-610-THGB-G12R
Module efficiency 22.83 % 22.58 % +0.25 pp for 590 TB M10_1A
Power density 228.4 Wp/m² 225.8 Wp/m² Effectively the same
Open-circuit voltage 51.42 V 49.06 V 2.36 V apart
Voltage at max power 44.15 V 41.39 V 2.76 V apart
Short-circuit current 14.04 A 15.62 A 1.58 A apart
Current at max power 13.37 A 14.74 A 1.37 A apart
Temperature
Temperature coefficient -0.300 %/°C -0.290 %/°C +0.010 %/°C for 132-610-THGB-G12R
Mechanical
Dimensions 2278x1134x35 mm 2382x1134x35 mm 2278x1134x35 mm vs 2382x1134x35 mm
Module area 2.583 m² 2.701 m² 0.118 m² apart
Weight 28.0 kg 33.5 kg -5.5 kg for 590 TB M10_1A
Weight per kWp 47.5 kg/kWp 54.9 kg/kWp -7.5 kg/kWp for 590 TB M10_1A
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon N-type TOPCon vs N-type
Cell type Monocrystalline Monocrystalline Same
Cell count 144 132 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,129 panels
Efficiency
#2,738 vs #3,887
590 TB M10_1A leads by 1,149 places
Power density
#2,653 vs #3,788
590 TB M10_1A leads by 1,135 places
Heat behaviour
#6,152 vs #2,220
132-610-THGB-G12R leads by 3,932 places
Weight
#1,689 vs #9,375
590 TB M10_1A leads by 7,686 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#3,701 vs #3,381
132-610-THGB-G12R leads by 320 places
05

More useful comparisons

Open the full database
Same series, other bin
Premier Energies
Premier Energies PE-590 TB M10_1A vs Premier Energies PE-585 TB M10_1A
One difference: module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-590 TB M10_1A vs Premier Energies PE-580 TB M10_1A
3 differences, the largest is module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-590 TB M10_1A vs Premier Energies PE-575 TB M10_1A
3 differences, the largest is module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-590 TB M10_1A vs Premier Energies PE-570 TB M10_1A
3 differences, the largest is module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-590 TB M10_1A vs Premier Energies PE-565 TB M10_1A
6 differences, the largest is module efficiency
Same series, other bin
Premier Energies
Premier Energies PE-590 TB M10_1A vs Premier Energies PE-560 TB M10_1A
6 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Premier Energies PE-590 TB M10_1A or Premier Energies PE-132-610-THGB-G12R?
According to our database: Premier Energies PE-590 TB M10_1A has higher module efficiency (22.83% vs 22.58%); Premier Energies PE-132-610-THGB-G12R tolerates heat better (temp coeff -0.290%/°C vs -0.300%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Premier Energies PE-590 TB M10_1A and Premier Energies PE-132-610-THGB-G12R?
Premier Energies PE-590 TB M10_1A has a module efficiency of 22.83%, while Premier Energies PE-132-610-THGB-G12R is 22.58%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Premier Energies PE-590 TB M10_1A use vs Premier Energies PE-132-610-THGB-G12R?
Premier Energies PE-590 TB M10_1A uses TOPCon cells; Premier Energies PE-132-610-THGB-G12R uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Premier Energies PE-590 TB M10_1A and Premier Energies PE-132-610-THGB-G12R?
Premier Energies PE-590 TB M10_1A has a 30 years power warranty; Premier Energies PE-132-610-THGB-G12R has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Premier Energies PE-590 TB M10_1A and Premier Energies PE-132-610-THGB-G12R bifacial panels?
Both Premier Energies PE-590 TB M10_1A and Premier Energies PE-132-610-THGB-G12R are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.