Skip to main content
LR7-54HVB-475M vs STP-NT11/48QGSF-475 8 of 18 identical Swap Change panels

Longi Solar LR7-54HVB-475M vs Suntech STP-NT11/48QGSF-475

Longi Solar LR7-54HVB-475M
LR7-54HVB-475M
475 Wp 23.30 % N-type
VS
Suntech STP-NT11/48QGSF-475
STP-NT11/48QGSF-475
475 Wp 23.80 % TOPCon
The verdict

STP-NT11/48QGSF-475 leads on the differences that matter

The largest is module efficiency: 0.50 pp more efficient. 8 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.

See all 10 differences
How alike are they
8 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 18 parameters
Parameter LR7-54HVB-475M STP-NT11/48QGSF-475 Difference
Module efficiency 23.30 % 23.80 % 0.50 pp more efficient
Open-circuit voltage 40.18 V 36.53 V 3.65 V apart
Power density 232.7 Wp/m² 237.7 Wp/m² 5.0 Wp/m² higher
Short-circuit current 15.03 A 16.43 A 1.40 A apart
Cell technology N-type TOPCon N-type vs TOPCon
Module area 2.041 m² 1.998 m² 0.043 m² apart
Cell count 108 192 84 cells apart
Voltage at max power 33.16 V 30.43 V 2.73 V apart
Current at max power 14.33 A 15.62 A 1.29 A apart
Dimensions 1800x1134x30 mm 1762x1134x30 mm 1800x1134x30 mm vs 1762x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.260 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
LR7-54HVB-475M
16,061 kWh
STP-NT11/48QGSF-475
16,061 kWh
Lifetime gap
No difference
Output when it is hot
Rated power carried across the range a module actually sees
Scenario LR7-54HVB-475M STP-NT11/48QGSF-475
Standard test conditions 25 °C 100.0% of rated power 475 W 475 W
Cool, bright day 40 °C 96.1% of rated power 456 W 456 W
Typical summer roof 55 °C 92.2% of rated power 438 W 438 W
Hot roof 70 °C 88.3% of rated power 419 W 419 W
03

Full specification

Parameter LR7-54HVB-475M STP-NT11/48QGSF-475 Difference
Power and efficiency
Rated power 475 Wp 475 Wp Same
Module efficiency 23.30 % 23.80 % +0.50 pp for STP-NT11/48QGSF-475
Power density 232.7 Wp/m² 237.7 Wp/m² +5.0 Wp/m² for STP-NT11/48QGSF-475
Open-circuit voltage 40.18 V 36.53 V 3.65 V apart
Voltage at max power 33.16 V 30.43 V 2.73 V apart
Short-circuit current 15.03 A 16.43 A 1.40 A apart
Current at max power 14.33 A 15.62 A 1.29 A apart
Temperature
Temperature coefficient -0.260 %/°C -0.260 %/°C Same
Mechanical
Dimensions 1800x1134x30 mm 1762x1134x30 mm 1800x1134x30 mm vs 1762x1134x30 mm
Module area 2.041 m² 1.998 m² 0.043 m² apart
Weight 21.6 kg 21.5 kg Effectively the same
Weight per kWp 45.5 kg/kWp 45.3 kg/kWp Effectively the same
Warranty and degradation
Product warranty - 25 yrs Not published by Longi Solar
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.35 %/yr 0.35 %/yr Same
Technology
Cell technology N-type TOPCon N-type vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count 108 192 84 cells apart
Bifacial No No Same
04

Against the whole database

14,129 panels
Efficiency
#1,057 vs #462
STP-NT11/48QGSF-475 leads by 595 places
Power density
#1,231 vs #497
STP-NT11/48QGSF-475 leads by 734 places
Heat behaviour
#515 vs #515
Tied - the same position in the database
Weight
#743 vs #669
STP-NT11/48QGSF-475 leads by 74 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#9,602 vs #3,803
STP-NT11/48QGSF-475 leads by 5,799 places
05

More useful comparisons

Open the full database
Same series, other bin
Longi Solar LR7-54HVB-475M vs Longi Solar LR7-54HVB-495M
3 differences, the largest is module efficiency
Same series, other bin
Longi Solar LR7-54HVB-475M vs Longi Solar LR7-54HVB-490M
3 differences, the largest is module efficiency
Same series, other bin
Longi Solar LR7-54HVB-475M vs Longi Solar LR7-54HVB-485M
3 differences, the largest is module efficiency
Same series, other bin
Longi Solar LR7-54HVB-475M vs Longi Solar LR7-54HVB-480M
One difference: module efficiency
Same series, other bin
Suntech STP-NT11/48QGSF-475 vs Suntech STP730S-D66-Nsh+
15 differences, the largest is rated power
Same series, other bin
Suntech STP-NT11/48QGSF-475 vs Suntech STP-NT11/66QGDF-670
12 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Longi Solar LR7-54HVB-475M or Suntech STP-NT11/48QGSF-475?
According to our database: Suntech STP-NT11/48QGSF-475 has higher module efficiency (23.80% vs 23.30%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Longi Solar LR7-54HVB-475M and Suntech STP-NT11/48QGSF-475?
Longi Solar LR7-54HVB-475M has a module efficiency of 23.30%, while Suntech STP-NT11/48QGSF-475 is 23.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Longi Solar LR7-54HVB-475M use vs Suntech STP-NT11/48QGSF-475?
Longi Solar LR7-54HVB-475M uses N-type cells; Suntech STP-NT11/48QGSF-475 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Longi Solar LR7-54HVB-475M and Suntech STP-NT11/48QGSF-475?
Longi Solar LR7-54HVB-475M has a 30 years power warranty; Suntech STP-NT11/48QGSF-475 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Compare Longi Solar and Suntech as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 147 Longi Solar offers · See 14 Suntech offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.