Skip to main content
510/LB vs 485/LB 13 of 19 identical Swap Change panels

JA Solar JAM60D41 510/LB vs JA Solar JAM60D41 485/LB

JA Solar JAM60D41 510/LB
JAM60D41 510/LB
510 Wp 23.00 % TOPCon Bifacial
VS
JA Solar JAM60D41 485/LB
JAM60D41 485/LB
485 Wp 21.90 % TOPCon Bifacial
The verdict

510/LB leads on the differences that matter

The largest is module efficiency: 1.10 pp more efficient. 13 of 19 comparable parameters are identical.

See all 6 differences
How alike are they
13 of 19 comparable
parameters are identical
identical differs
01

What actually differs

6 of 19 parameters
Parameter 510/LB 485/LB Difference
Module efficiency 23.00 % 21.90 % 1.10 pp more efficient
Power density 230.3 Wp/m² 219.0 Wp/m² 11.3 Wp/m² higher
Rated power 510 Wp 485 Wp 25 W more power
Weight per kWp 53.5 kg/kWp 56.3 kg/kWp 2.8 kg/kWp lighter
Open-circuit voltage 44.25 V 43.25 V 1.00 V apart
Voltage at max power 37.31 V 36.28 V 1.03 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
510/LB
17,112 kWh
485/LB
16,273 kWh
Lifetime gap
839 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 510/LB 485/LB
Standard test conditions 25 °C 100.0% of rated power 510 W 485 W
Cool, bright day 40 °C 95.7% of rated power 488 W 464 W
Typical summer roof 55 °C 91.3% of rated power 466 W 443 W
Hot roof 70 °C 87.0% of rated power 443 W 422 W
03

Full specification

Parameter 510/LB 485/LB Difference
Power and efficiency
Rated power 510 Wp 485 Wp +25 W for 510/LB
Module efficiency 23.00 % 21.90 % +1.10 pp for 510/LB
Power density 230.3 Wp/m² 219.0 Wp/m² +11.3 Wp/m² for 510/LB
Open-circuit voltage 44.25 V 43.25 V 1.00 V apart
Voltage at max power 37.31 V 36.28 V 1.03 V apart
Short-circuit current 14.54 A 14.24 A Effectively the same
Current at max power 13.67 A 13.37 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1953x1134x30 mm 1953x1134x30 mm Same
Module area 2.215 m² 2.215 m² Same
Weight 27.3 kg 27.3 kg Same
Weight per kWp 53.5 kg/kWp 56.3 kg/kWp -2.8 kg/kWp for 510/LB
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 120 120 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#1,919 vs #6,783
510/LB leads by 4,864 places
Power density
#1,849 vs #6,767
510/LB leads by 4,918 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#7,509 vs #10,551
510/LB leads by 3,042 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#6,280 vs #8,670
510/LB leads by 2,390 places
05

More useful comparisons

Open the full database
Same series, other bin
JA Solar JAM60D41 510/LB vs JA Solar JAM60D42-545/LB
7 differences, the largest is rated power
Same series, other bin
JA Solar JAM60D41 510/LB vs JA Solar JAM60D42-540/LB
6 differences, the largest is rated power
Same series, other bin
JA Solar JAM60D41 510/LB vs JA Solar JAM60D42-535/LB
6 differences, the largest is rated power
Same series, other bin
JA Solar JAM60D41 510/LB vs JA Solar JAM60D42-530/LB
8 differences, the largest is rated power
Same series, other bin
JA Solar JAM60D41 510/LB vs JA Solar JAM60D42-525/LB
8 differences, the largest is module efficiency
Same series, other bin
JA Solar JAM60D41 510/LB vs JA Solar JAM60D42-520/LB
8 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: JA Solar JAM60D41 510/LB or JA Solar JAM60D41 485/LB?
According to our database: JA Solar JAM60D41 510/LB has higher module efficiency (23.00% vs 21.90%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of JA Solar JAM60D41 510/LB and JA Solar JAM60D41 485/LB?
JA Solar JAM60D41 510/LB has a module efficiency of 23.00%, while JA Solar JAM60D41 485/LB is 21.90%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does JA Solar JAM60D41 510/LB use vs JA Solar JAM60D41 485/LB?
JA Solar JAM60D41 510/LB uses TOPCon cells; JA Solar JAM60D41 485/LB uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on JA Solar JAM60D41 510/LB and JA Solar JAM60D41 485/LB?
JA Solar JAM60D41 510/LB has a 30 years power warranty; JA Solar JAM60D41 485/LB has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are JA Solar JAM60D41 510/LB and JA Solar JAM60D41 485/LB bifacial panels?
Both JA Solar JAM60D41 510/LB and JA Solar JAM60D41 485/LB are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 352 JA Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.