HT-SAAE HT72-18X 550W vs HT-SAAE HT66-210(ND)-F 705W
VS
The verdict
HT66-210(ND)-F 705W leads on the differences that matter
The largest is module efficiency: 1.40 pp more efficient. 2 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 16 differencesHow alike are they
2
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 18 parameters
What actually differs
Parameter
HT72-18X 550W
HT66-210(ND)-F 705W
Difference
Module efficiency
21.30 %
22.70 %
1.40 pp more efficient
Rated power
550 Wp
705 Wp
155 W more power
Power density
212.8 Wp/m²
227.0 Wp/m²
14.1 Wp/m² higher
Performance warranty
25 yrs
30 yrs
5 yrs longer
Weight
28.5 kg
38.5 kg
10.0 kg lighter
Product warranty
25 yrs
30 yrs
5 yrs longer
Temperature coefficient
-0.330 %/°C
-0.310 %/°C
0.020 %/°C better in heat
Short-circuit current
14.00 A
18.41 A
4.41 A apart
Module area
2.584 m²
3.106 m²
0.522 m² apart
Cell technology
PERC
TOPCon
PERC vs TOPCon
Weight per kWp
51.8 kg/kWp
54.6 kg/kWp
2.8 kg/kWp lighter
Current at max power
13.12 A
17.16 A
4.04 A apart
Cell count
144
132
12 cells apart
Open-circuit voltage
49.80 V
48.00 V
1.80 V apart
Bifacial
No
Yes
No vs Yes
Dimensions
2279x1134x35 mm
2384x1303x35 mm
2279x1134x35 mm vs 2384x1303x35 mm
02
What it means on a roof
Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
HT72-18X 550W
18,157 kWh
HT66-210(ND)-F 705W
23,654 kWh
Lifetime gap
5,497 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
HT72-18X 550W
HT66-210(ND)-F 705W
Standard test conditions
25 °C
100.0% of rated power
550 W
705 W
Cool, bright day
40 °C
95.0% of rated power
523 W
672 W
Typical summer roof
55 °C
90.1% of rated power
496 W
639 W
Hot roof
70 °C
85.2% of rated power
468 W
607 W
03
Full specification
Parameter
HT72-18X 550W
HT66-210(ND)-F 705W
Difference
Power and efficiency
Rated power
550 Wp
705 Wp
+155 W for HT66-210(ND)-F 705W
Module efficiency
21.30 %
22.70 %
+1.40 pp for HT66-210(ND)-F 705W
Power density
212.8 Wp/m²
227.0 Wp/m²
+14.1 Wp/m² for HT66-210(ND)-F 705W
Open-circuit voltage
49.80 V
48.00 V
1.80 V apart
Voltage at max power
41.95 V
41.10 V
Effectively the same
Short-circuit current
14.00 A
18.41 A
4.41 A apart
Current at max power
13.12 A
17.16 A
4.04 A apart
Temperature
Temperature coefficient
-0.330 %/°C
-0.310 %/°C
+0.020 %/°C for HT66-210(ND)-F 705W
Mechanical
Dimensions
2279x1134x35 mm
2384x1303x35 mm
2279x1134x35 mm vs 2384x1303x35 mm
Module area
2.584 m²
3.106 m²
0.522 m² apart
Weight
28.5 kg
38.5 kg
-10.0 kg for HT72-18X 550W
Weight per kWp
51.8 kg/kWp
54.6 kg/kWp
-2.8 kg/kWp for HT72-18X 550W
Warranty and degradation
Product warranty
25 yrs
30 yrs
+5 yrs for HT66-210(ND)-F 705W
Performance warranty
25 yrs
30 yrs
+5 yrs for HT66-210(ND)-F 705W
Annual degradation
-
0.40 %/yr
Not published by HT-SAAE
Technology
Cell technology
PERC
TOPCon
PERC vs TOPCon
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
132
12 cells apart
Bifacial
No
Yes
No vs Yes
04
14,129 panels
Against the whole database
Efficiency
#8,585
vs
#3,364
HT66-210(ND)-F 705W leads by 5,221 places
Power density
#8,709
vs
#3,418
HT66-210(ND)-F 705W leads by 5,291 places
Heat behaviour
#8,613
vs
#8,069
HT66-210(ND)-F 705W leads by 544 places
Weight
#5,236
vs
#9,041
HT72-18X 550W leads by 3,805 places
Warranty
#9,912
vs
#21
HT66-210(ND)-F 705W leads by 9,891 places
Overall
#5,257
vs
#85
HT66-210(ND)-F 705W leads by 5,172 places
05
Open the full database
More useful comparisons
Same series, other bin
HT-SAAE
HT-SAAE HT72-18X 550W vs HT-SAAE HT72-18X 560W
3 differences, the largest is module efficiency
Same series, other bin
HT-SAAE
HT-SAAE HT72-18X 550W vs HT-SAAE HT72-18X 555W
One difference: module efficiency
Same series, other bin
HT-SAAE
HT-SAAE HT72-18X 550W vs HT-SAAE HT72-18X 545W
One difference: module efficiency
Same series, other bin
HT-SAAE
HT-SAAE HT72-18X 550W vs HT-SAAE HT72-18X 540W
3 differences, the largest is module efficiency
Same series, other bin
HT-SAAE
HT-SAAE HT66-210(ND)-F 705W vs HT-SAAE HT66-210(ND)-F 715W
3 differences, the largest is module efficiency
Same series, other bin
HT-SAAE
HT-SAAE HT66-210(ND)-F 705W vs HT-SAAE HT66-210(ND)-F 710W
One difference: module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: HT-SAAE HT72-18X 550W or HT-SAAE HT66-210(ND)-F 705W?
According to our database: HT-SAAE HT66-210(ND)-F 705 W has higher module efficiency (22.70% vs 21.30%); HT-SAAE HT66-210(ND)-F 705 W tolerates heat better (temp coeff -0.310%/°C vs -0.330%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of HT-SAAE HT72-18X 550W and HT-SAAE HT66-210(ND)-F 705W?
HT-SAAE HT72-18X 550 W has a module efficiency of 21.30%, while HT-SAAE HT66-210(ND)-F 705 W is 22.70%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does HT-SAAE HT72-18X 550W use vs HT-SAAE HT66-210(ND)-F 705W?
HT-SAAE HT72-18X 550 W uses PERC cells; HT-SAAE HT66-210(ND)-F 705 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on HT-SAAE HT72-18X 550W and HT-SAAE HT66-210(ND)-F 705W?
HT-SAAE HT72-18X 550 W has a 25 years power warranty; HT-SAAE HT66-210(ND)-F 705 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are HT-SAAE HT72-18X 550W and HT-SAAE HT66-210(ND)-F 705W bifacial panels?
HT-SAAE HT66-210(ND)-F 705 W is bifacial (captures light from both faces); HT-SAAE HT72-18X 550 W is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.