Skip to main content
HS450TC-MHC-D vs AIKO-455-MAH54Db 5 of 18 identical Swap Change panels

Horay Solar HS450TC-MHC-D vs AIKO AIKO-455-MAH54Db

HS450TC-MHC-D
450 Wp 22.50 % TOPCon Bifacial Incomplete
VS
AIKO AIKO-455-MAH54Db
AIKO-455-MAH54Db
455 Wp 23.30 % Back Contact
The verdict

AIKO-455-MAH54Db leads on the differences that matter

The largest is module efficiency: 0.80 pp more efficient. 5 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.

See all 13 differences
How alike are they
5 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 18 parameters
Parameter HS450TC-MHC-D AIKO-455-MAH54Db Difference
Module efficiency 22.50 % 23.30 % 0.80 pp more efficient
Product warranty 15 yrs 25 yrs 10 yrs longer
Power density 225.2 Wp/m² 233.0 Wp/m² 7.8 Wp/m² higher
Temperature coefficient -0.280 %/°C -0.260 %/°C 0.020 %/°C better in heat
Open-circuit voltage 36.04 V 40.35 V 4.31 V apart
Short-circuit current 15.87 A 13.80 A 2.07 A apart
Cell technology TOPCon Back Contact TOPCon vs Back Contact
Module area 1.998 m² 1.953 m² 0.045 m² apart
Voltage at max power 29.95 V 33.99 V 4.04 V apart
Cell count 96 108 12 cells apart
Current at max power 15.02 A 13.39 A 1.63 A apart
Bifacial Yes No Yes vs No
Dimensions 1762x1134x30 mm 1722x1134x30 mm 1762x1134x30 mm vs 1722x1134x30 mm
02

What it means on a roof

Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
HS450TC-MHC-D
15,098 kWh
AIKO-455-MAH54Db
15,266 kWh
Lifetime gap
168 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario HS450TC-MHC-D AIKO-455-MAH54Db
Standard test conditions 25 °C 100.0% of rated power 450 W 455 W
Cool, bright day 40 °C 95.8% of rated power 431 W 437 W
Typical summer roof 55 °C 91.6% of rated power 412 W 420 W
Hot roof 70 °C 87.4% of rated power 393 W 402 W
03

Full specification

Parameter HS450TC-MHC-D AIKO-455-MAH54Db Difference
Power and efficiency
Rated power 450 Wp 455 Wp Effectively the same
Module efficiency 22.50 % 23.30 % +0.80 pp for AIKO-455-MAH54Db
Power density 225.2 Wp/m² 233.0 Wp/m² +7.8 Wp/m² for AIKO-455-MAH54Db
Open-circuit voltage 36.04 V 40.35 V 4.31 V apart
Voltage at max power 29.95 V 33.99 V 4.04 V apart
Short-circuit current 15.87 A 13.80 A 2.07 A apart
Current at max power 15.02 A 13.39 A 1.63 A apart
Temperature
Temperature coefficient -0.280 %/°C -0.260 %/°C +0.020 %/°C for AIKO-455-MAH54Db
Mechanical
Dimensions 1762x1134x30 mm 1722x1134x30 mm 1762x1134x30 mm vs 1722x1134x30 mm
Module area 1.998 m² 1.953 m² 0.045 m² apart
Weight 24.5 kg 24.0 kg Effectively the same
Weight per kWp 54.4 kg/kWp 52.7 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 25 yrs +10 yrs for AIKO-455-MAH54Db
Performance warranty 30 yrs 30 yrs Same
Annual degradation - 0.35 %/yr Not published by Horay Solar
Technology
Cell technology TOPCon Back Contact TOPCon vs Back Contact
Cell type Monocrystalline Monocrystalline Same
Cell count 96 108 12 cells apart
Bifacial Yes No Yes vs No
04

Against the whole database

14,005 panels
Efficiency
#4,222 vs #1,017
AIKO-455-MAH54Db leads by 3,205 places
Power density
#4,225 vs #1,098
AIKO-455-MAH54Db leads by 3,127 places
Heat behaviour
#1,309 vs #511
AIKO-455-MAH54Db leads by 798 places
Weight
#8,755 vs #6,401
AIKO-455-MAH54Db leads by 2,354 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#8,540 vs #5,104
AIKO-455-MAH54Db leads by 3,436 places
05

More useful comparisons

Open the full database
Same series, other bin
Horay Solar HS450TC-MHC-D vs Horay Solar HS455TC-MHC-D
One difference: module efficiency
Same series, other bin
Horay Solar HS450TC-MHC-D vs Horay Solar HS445TC-MHC-D
One difference: module efficiency
Same series, other bin
Horay Solar HS450TC-MHC-D vs Horay Solar HS440TC-MHC-D
3 differences, the largest is module efficiency
Same series, other bin
Horay Solar HS450TC-MHC-D vs Horay Solar HS435TC-MHC-D
3 differences, the largest is module efficiency
Same manufacturer
Horay Solar HS450TC-MHC-D vs Horay Solar HS720TC-MHG-D
11 differences, the largest is module efficiency
Same manufacturer
Horay Solar HS450TC-MHC-D vs Horay Solar HS710TC-MHG-D
11 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Horay Solar HS450TC-MHC-D or AIKO AIKO-455-MAH54Db?
According to our database: AIKO AIKO-455-MAH54Db has higher module efficiency (23.30% vs 22.50%); AIKO AIKO-455-MAH54Db tolerates heat better (temp coeff -0.260%/°C vs -0.280%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Horay Solar HS450TC-MHC-D and AIKO AIKO-455-MAH54Db?
Horay Solar HS450TC-MHC-D has a module efficiency of 22.50%, while AIKO AIKO-455-MAH54Db is 23.30%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Horay Solar HS450TC-MHC-D use vs AIKO AIKO-455-MAH54Db?
Horay Solar HS450TC-MHC-D uses TOPCon cells; AIKO AIKO-455-MAH54Db uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Horay Solar HS450TC-MHC-D and AIKO AIKO-455-MAH54Db?
Horay Solar HS450TC-MHC-D has a 30 years power warranty; AIKO AIKO-455-MAH54Db has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Horay Solar HS450TC-MHC-D and AIKO AIKO-455-MAH54Db bifacial panels?
Horay Solar HS450TC-MHC-D is bifacial (captures light from both faces); AIKO AIKO-455-MAH54Db is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Compare Horay Solar and AIKO as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 171 AIKO offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.