GCL NT12R/54BGDF-515W vs GCL NT12R/48GDF-455W
VS
The verdict
54BGDF-515W leads on the differences that matter
The largest is rated power: 60 W more power. 9 of 19 comparable parameters are identical.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
10 of 19 parameters
What actually differs
Parameter
54BGDF-515W
48GDF-455W
Difference
Rated power
515 Wp
455 Wp
60 W more power
Module efficiency
23.15 %
22.77 %
0.38 pp more efficient
Weight
27.3 kg
24.5 kg
2.8 kg lighter
Open-circuit voltage
41.19 V
35.30 V
5.89 V apart
Module area
2.225 m²
1.998 m²
0.227 m² apart
Power density
231.5 Wp/m²
227.7 Wp/m²
3.8 Wp/m² higher
Voltage at max power
34.75 V
29.94 V
4.81 V apart
Cell count
108
96
12 cells apart
Short-circuit current
15.50 A
16.00 A
0.50 A apart
Dimensions
1962x1134x30 mm
1762x1134x30 mm
1962x1134x30 mm vs 1762x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
54BGDF-515W
17,279 kWh
48GDF-455W
15,266 kWh
Lifetime gap
2,013 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
54BGDF-515W
48GDF-455W
Standard test conditions
25 °C
100.0% of rated power
515 W
455 W
Cool, bright day
40 °C
95.7% of rated power
493 W
435 W
Typical summer roof
55 °C
91.3% of rated power
470 W
415 W
Hot roof
70 °C
87.0% of rated power
448 W
396 W
03
Full specification
Parameter
54BGDF-515W
48GDF-455W
Difference
Power and efficiency
Rated power
515 Wp
455 Wp
+60 W for 54BGDF-515W
Module efficiency
23.15 %
22.77 %
+0.38 pp for 54BGDF-515W
Power density
231.5 Wp/m²
227.7 Wp/m²
+3.8 Wp/m² for 54BGDF-515W
Open-circuit voltage
41.19 V
35.30 V
5.89 V apart
Voltage at max power
34.75 V
29.94 V
4.81 V apart
Short-circuit current
15.50 A
16.00 A
0.50 A apart
Current at max power
14.82 A
15.20 A
Effectively the same
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1962x1134x30 mm
1762x1134x30 mm
1962x1134x30 mm vs 1762x1134x30 mm
Module area
2.225 m²
1.998 m²
0.227 m² apart
Weight
27.3 kg
24.5 kg
-2.8 kg for 48GDF-455W
Weight per kWp
53.0 kg/kWp
53.8 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
96
12 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#1,503
vs
#3,073
54BGDF-515W leads by 1,570 places
Power density
#1,499
vs
#2,888
54BGDF-515W leads by 1,389 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#6,762
vs
#7,897
54BGDF-515W leads by 1,135 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#5,886
vs
#8,644
54BGDF-515W leads by 2,758 places
05
Open the full database
More useful comparisons
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL GCL-NT12R/54GDF-530
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL NT12R/54GDF-525W
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL GCL-NT12R/54GDF-525
5 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL NT12R/54BGDF-520W
One difference: module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL NT12R/54GDF-520W
3 differences, the largest is module efficiency
Same series, other bin
GCL NT12R/54BGDF-515W vs GCL GCL-NT12R/54GDF-520
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: GCL NT12R/54BGDF-515W or GCL NT12R/48GDF-455W?
According to our database: GCL NT12R/54BGDF-515 W has higher module efficiency (23.15% vs 22.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL NT12R/54BGDF-515W and GCL NT12R/48GDF-455W?
GCL NT12R/54BGDF-515 W has a module efficiency of 23.15%, while GCL NT12R/48GDF-455 W is 22.77%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL NT12R/54BGDF-515W use vs GCL NT12R/48GDF-455W?
GCL NT12R/54BGDF-515 W uses TOPCon cells; GCL NT12R/48GDF-455 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL NT12R/54BGDF-515W and GCL NT12R/48GDF-455W?
GCL NT12R/54BGDF-515 W has a 30 years power warranty; GCL NT12R/48GDF-455 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL NT12R/54BGDF-515W and GCL NT12R/48GDF-455W bifacial panels?
Both GCL NT12R/54BGDF-515 W and GCL NT12R/48GDF-455 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 5 GCL offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.