Skip to main content
580 MV vs 450 M 6 of 19 identical Swap Change panels

FuturaSun FU 580 MV vs FuturaSun FU 450 M

FuturaSun
FU 580 MV
580 Wp 22.40 % TOPCon Bifacial
VS
FuturaSun
FU 450 M
450 Wp 22.52 % PERC
The verdict

13 differences, and they point both ways

The largest is rated power: 130 W more power. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter 580 MV 450 M Difference
Rated power 580 Wp 450 Wp 130 W more power
Performance warranty 30 yrs 25 yrs 5 yrs longer
Weight 32.0 kg 21.3 kg 10.7 kg lighter
Weight per kWp 55.2 kg/kWp 47.3 kg/kWp 7.8 kg/kWp lighter
Open-circuit voltage 51.00 V 35.47 V 15.53 V apart
Module area 2.583 m² 1.998 m² 0.585 m² apart
Short-circuit current 14.48 A 15.97 A 1.49 A apart
Cell technology TOPCon PERC TOPCon vs PERC
Voltage at max power 42.34 V 30.01 V 12.33 V apart
Cell count 144 96 48 cells apart
Bifacial Yes No Yes vs No
Current at max power 13.70 A 15.00 A 1.30 A apart
Dimensions 2278x1134x30 mm 1762x1134x30 mm 2278x1134x30 mm vs 1762x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
580 MV
19,460 kWh
450 M
15,098 kWh
Lifetime gap
4,362 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 580 MV 450 M
Standard test conditions 25 °C 100.0% of rated power 580 W 450 W
Cool, bright day 40 °C 95.7% of rated power 555 W 430 W
Typical summer roof 55 °C 91.3% of rated power 530 W 411 W
Hot roof 70 °C 87.0% of rated power 504 W 391 W
03

Full specification

Parameter 580 MV 450 M Difference
Power and efficiency
Rated power 580 Wp 450 Wp +130 W for 580 MV
Module efficiency 22.40 % 22.52 % Effectively the same
Power density 224.5 Wp/m² 225.2 Wp/m² Effectively the same
Open-circuit voltage 51.00 V 35.47 V 15.53 V apart
Voltage at max power 42.34 V 30.01 V 12.33 V apart
Short-circuit current 14.48 A 15.97 A 1.49 A apart
Current at max power 13.70 A 15.00 A 1.30 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2278x1134x30 mm 1762x1134x30 mm 2278x1134x30 mm vs 1762x1134x30 mm
Module area 2.583 m² 1.998 m² 0.585 m² apart
Weight 32.0 kg 21.3 kg -10.7 kg for 450 M
Weight per kWp 55.2 kg/kWp 47.3 kg/kWp -7.8 kg/kWp for 450 M
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 25 yrs +5 yrs for 580 MV
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon PERC TOPCon vs PERC
Cell type Monocrystalline Monocrystalline Same
Cell count 144 96 48 cells apart
Bifacial Yes No Yes vs No
04

Against the whole database

14,129 panels
Efficiency
#4,834 vs #4,167
450 M leads by 667 places
Power density
#4,607 vs #4,284
450 M leads by 323 places
Heat behaviour
#2,220 vs #2,220
Tied - the same position in the database
Weight
#9,671 vs #1,641
450 M leads by 8,030 places
Warranty
#21 vs #9,912
580 MV leads by 9,891 places
Overall
#4,065 vs #9,413
580 MV leads by 5,348 places
05

More useful comparisons

Open the full database
Same series, other bin
FuturaSun
FuturaSun FU 580 MV vs FuturaSun FU 720 MV
12 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 580 MV vs FuturaSun FU 710 MV
11 differences, the largest is rated power
Same series, other bin
FuturaSun
FuturaSun FU 580 MV vs FuturaSun FU 700 MV
9 differences, the largest is rated power
Same series, other bin
FuturaSun
FuturaSun FU 580 MV vs FuturaSun FU 590 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 580 MV vs FuturaSun FU 585 MV
One difference: module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 580 MV vs FuturaSun FU 575 MV
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: FuturaSun FU 580 MV or FuturaSun FU 450 M?
According to our database: FuturaSun FU 450 M has higher module efficiency (22.52% vs 22.40%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 580 MV and FuturaSun FU 450 M?
FuturaSun FU 580 MV has a module efficiency of 22.40%, while FuturaSun FU 450 M is 22.52%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 580 MV use vs FuturaSun FU 450 M?
FuturaSun FU 580 MV uses TOPCon cells; FuturaSun FU 450 M uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 580 MV and FuturaSun FU 450 M?
FuturaSun FU 580 MV has a 30 years power warranty; FuturaSun FU 450 M has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are FuturaSun FU 580 MV and FuturaSun FU 450 M bifacial panels?
FuturaSun FU 580 MV is bifacial (captures light from both faces); FuturaSun FU 450 M is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 8 FuturaSun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.