Skip to main content
575 MV vs 570 MV 18 of 19 identical Swap Change panels

FuturaSun FU 575 MV vs FuturaSun FU 570 MV

FuturaSun
FU 575 MV
575 Wp 22.20 % TOPCon Bifacial
VS
FuturaSun
FU 570 MV
570 Wp 22.00 % TOPCon Bifacial
The verdict

575 MV leads on the differences that matter

The largest is module efficiency: 0.20 pp more efficient. 18 of 19 comparable parameters are identical.

See the one difference
How alike are they
18 of 19 comparable
parameters are identical
identical differs
01

What actually differs

1 of 19 parameters
Parameter 575 MV 570 MV Difference
Module efficiency 22.20 % 22.00 % 0.20 pp more efficient
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
575 MV
19,292 kWh
570 MV
19,125 kWh
Lifetime gap
167 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 575 MV 570 MV
Standard test conditions 25 °C 100.0% of rated power 575 W 570 W
Cool, bright day 40 °C 95.7% of rated power 550 W 545 W
Typical summer roof 55 °C 91.3% of rated power 525 W 520 W
Hot roof 70 °C 87.0% of rated power 500 W 496 W
03

Full specification

Parameter 575 MV 570 MV Difference
Power and efficiency
Rated power 575 Wp 570 Wp Effectively the same
Module efficiency 22.20 % 22.00 % +0.20 pp for 575 MV
Power density 222.6 Wp/m² 220.7 Wp/m² Effectively the same
Open-circuit voltage 50.86 V 50.72 V Effectively the same
Voltage at max power 42.19 V 42.04 V Effectively the same
Short-circuit current 14.40 A 14.32 A Effectively the same
Current at max power 13.63 A 13.56 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 2278x1134x30 mm 2278x1134x30 mm Same
Module area 2.583 m² 2.583 m² Same
Weight 32.0 kg 32.0 kg Same
Weight per kWp 55.7 kg/kWp 56.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 144 144 Same
Bifacial Yes Yes Same
04

Against the whole database

14,129 panels
Efficiency
#5,881 vs #6,580
575 MV leads by 699 places
Power density
#5,612 vs #6,121
575 MV leads by 509 places
Heat behaviour
#2,220 vs #2,220
Tied - the same position in the database
Weight
#10,101 vs #10,498
575 MV leads by 397 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#4,457 vs #4,861
575 MV leads by 404 places
05

More useful comparisons

Open the full database
Same series, other bin
FuturaSun
FuturaSun FU 575 MV vs FuturaSun FU 720 MV
11 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 575 MV vs FuturaSun FU 710 MV
11 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 575 MV vs FuturaSun FU 700 MV
10 differences, the largest is rated power
Same series, other bin
FuturaSun
FuturaSun FU 575 MV vs FuturaSun FU 590 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 575 MV vs FuturaSun FU 585 MV
3 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 575 MV vs FuturaSun FU 580 MV
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: FuturaSun FU 575 MV or FuturaSun FU 570 MV?
According to our database: FuturaSun FU 575 MV has higher module efficiency (22.20% vs 22.00%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 575 MV and FuturaSun FU 570 MV?
FuturaSun FU 575 MV has a module efficiency of 22.20%, while FuturaSun FU 570 MV is 22.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 575 MV use vs FuturaSun FU 570 MV?
FuturaSun FU 575 MV uses TOPCon cells; FuturaSun FU 570 MV uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 575 MV and FuturaSun FU 570 MV?
FuturaSun FU 575 MV has a 30 years power warranty; FuturaSun FU 570 MV has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are FuturaSun FU 575 MV and FuturaSun FU 570 MV bifacial panels?
Both FuturaSun FU 575 MV and FuturaSun FU 570 MV are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 8 FuturaSun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.