FuturaSun FU 450 M vs FuturaSun FU 710 MV
VS
The verdict
710 MV leads on the differences that matter
The largest is rated power: 260 W more power. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
450 M
710 MV
Difference
Rated power
450 Wp
710 Wp
260 W more power
Performance warranty
25 yrs
30 yrs
5 yrs longer
Weight
21.3 kg
38.2 kg
16.9 kg lighter
Weight per kWp
47.3 kg/kWp
53.8 kg/kWp
6.5 kg/kWp lighter
Module efficiency
22.52 %
22.86 %
0.34 pp more efficient
Open-circuit voltage
35.47 V
48.66 V
13.19 V apart
Short-circuit current
15.97 A
18.46 A
2.49 A apart
Module area
1.998 m²
3.106 m²
1.108 m² apart
Cell technology
PERC
TOPCon
PERC vs TOPCon
Power density
225.2 Wp/m²
228.6 Wp/m²
3.4 Wp/m² higher
Voltage at max power
30.01 V
40.89 V
10.88 V apart
Current at max power
15.00 A
17.37 A
2.37 A apart
Cell count
96
132
36 cells apart
Bifacial
No
Yes
No vs Yes
Dimensions
1762x1134x30 mm
2384x1303x33 mm
1762x1134x30 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
450 M
15,098 kWh
710 MV
23,822 kWh
Lifetime gap
8,724 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
450 M
710 MV
Standard test conditions
25 °C
100.0% of rated power
450 W
710 W
Cool, bright day
40 °C
95.7% of rated power
430 W
679 W
Typical summer roof
55 °C
91.3% of rated power
411 W
648 W
Hot roof
70 °C
87.0% of rated power
391 W
617 W
03
Full specification
Parameter
450 M
710 MV
Difference
Power and efficiency
Rated power
450 Wp
710 Wp
+260 W for 710 MV
Module efficiency
22.52 %
22.86 %
+0.34 pp for 710 MV
Power density
225.2 Wp/m²
228.6 Wp/m²
+3.4 Wp/m² for 710 MV
Open-circuit voltage
35.47 V
48.66 V
13.19 V apart
Voltage at max power
30.01 V
40.89 V
10.88 V apart
Short-circuit current
15.97 A
18.46 A
2.49 A apart
Current at max power
15.00 A
17.37 A
2.37 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1762x1134x30 mm
2384x1303x33 mm
1762x1134x30 mm vs 2384x1303x33 mm
Module area
1.998 m²
3.106 m²
1.108 m² apart
Weight
21.3 kg
38.2 kg
-16.9 kg for 450 M
Weight per kWp
47.3 kg/kWp
53.8 kg/kWp
-6.5 kg/kWp for 450 M
Warranty and degradation
Product warranty
15 yrs
15 yrs
Same
Performance warranty
25 yrs
30 yrs
+5 yrs for 710 MV
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
PERC
TOPCon
PERC vs TOPCon
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
96
132
36 cells apart
Bifacial
No
Yes
No vs Yes
04
14,129 panels
Against the whole database
Efficiency
#4,167
vs
#2,591
710 MV leads by 1,576 places
Power density
#4,284
vs
#2,529
710 MV leads by 1,755 places
Heat behaviour
#2,220
vs
#2,220
Tied - the same position in the database
Weight
#1,641
vs
#7,959
450 M leads by 6,318 places
Warranty
#9,912
vs
#21
710 MV leads by 9,891 places
Overall
#9,413
vs
#618
710 MV leads by 8,795 places
05
Open the full database
More useful comparisons
Same series, other bin
FuturaSun
FuturaSun FU 450 M vs FuturaSun FU 720 MV
15 differences, the largest is module efficiency
Same series, other bin
FuturaSun
FuturaSun FU 450 M vs FuturaSun FU 700 MV
13 differences, the largest is rated power
Same series, other bin
FuturaSun
FuturaSun FU 450 M vs FuturaSun FU 590 MV
15 differences, the largest is rated power
Same series, other bin
FuturaSun
FuturaSun FU 450 M vs FuturaSun FU 585 MV
13 differences, the largest is rated power
Same series, other bin
FuturaSun
FuturaSun FU 450 M vs FuturaSun FU 580 MV
13 differences, the largest is rated power
Same series, other bin
FuturaSun
FuturaSun FU 450 M vs FuturaSun FU 575 MV
14 differences, the largest is rated power
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: FuturaSun FU 450 M or FuturaSun FU 710 MV?
According to our database: FuturaSun FU 710 MV has higher module efficiency (22.86% vs 22.52%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of FuturaSun FU 450 M and FuturaSun FU 710 MV?
FuturaSun FU 450 M has a module efficiency of 22.52%, while FuturaSun FU 710 MV is 22.86%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does FuturaSun FU 450 M use vs FuturaSun FU 710 MV?
FuturaSun FU 450 M uses PERC cells; FuturaSun FU 710 MV uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on FuturaSun FU 450 M and FuturaSun FU 710 MV?
FuturaSun FU 450 M has a 25 years power warranty; FuturaSun FU 710 MV has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are FuturaSun FU 450 M and FuturaSun FU 710 MV bifacial panels?
FuturaSun FU 710 MV is bifacial (captures light from both faces); FuturaSun FU 450 M is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 8 FuturaSun offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.