Skip to main content
BF26-445W vs BF10-545W-DG 8 of 19 identical Swap Change panels

Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-144-BF10-545W-DG

Aptos Solar DNA-144-BF26-445W
Aptos Solar
DNA-144-BF26-445W
445 Wp 20.47 % PERC Bifacial
VS
Aptos Solar DNA-144-BF10-545W-DG
Aptos Solar
DNA-144-BF10-545W-DG
545 Wp 21.09 % PERC Bifacial
The verdict

11 differences, and they point both ways

The largest is rated power: 100 W more power. 8 of 19 comparable parameters are identical.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs
01

What actually differs

11 of 19 parameters
Parameter BF26-445W BF10-545W-DG Difference
Rated power 445 Wp 545 Wp 100 W more power
Module efficiency 20.47 % 21.09 % 0.62 pp more efficient
Weight 24.1 kg 32.3 kg 8.2 kg lighter
Power density 204.7 Wp/m² 211.0 Wp/m² 6.2 Wp/m² higher
Short-circuit current 11.44 A 13.92 A 2.48 A apart
Module area 2.174 m² 2.583 m² 0.410 m² apart
Weight per kWp 54.2 kg/kWp 59.3 kg/kWp 5.1 kg/kWp lighter
Temperature coefficient -0.320 %/°C -0.335 %/°C 0.015 %/°C better in heat
Current at max power 10.86 A 12.38 A 1.52 A apart
Voltage at max power 41.00 V 44.00 V 3.00 V apart
Dimensions 2094x1038x35 mm 2278x1134x35 mm 2094x1038x35 mm vs 2278x1134x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
BF26-445W
14,445 kWh
BF10-545W-DG
17,697 kWh
Lifetime gap
3,252 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario BF26-445W BF10-545W-DG
Standard test conditions 25 °C 100.0% of rated power 445 W 545 W
Cool, bright day 40 °C 95.0% of rated power 424 W 518 W
Typical summer roof 55 °C 90.0% of rated power 402 W 490 W
Hot roof 70 °C 84.9% of rated power 381 W 463 W
03

Full specification

Parameter BF26-445W BF10-545W-DG Difference
Power and efficiency
Rated power 445 Wp 545 Wp +100 W for BF10-545W-DG
Module efficiency 20.47 % 21.09 % +0.62 pp for BF10-545W-DG
Power density 204.7 Wp/m² 211.0 Wp/m² +6.2 Wp/m² for BF10-545W-DG
Open-circuit voltage 49.20 V 49.65 V Effectively the same
Voltage at max power 41.00 V 44.00 V 3.00 V apart
Short-circuit current 11.44 A 13.92 A 2.48 A apart
Current at max power 10.86 A 12.38 A 1.52 A apart
Temperature
Temperature coefficient -0.320 %/°C -0.335 %/°C +0.015 %/°C for BF26-445W
Mechanical
Dimensions 2094x1038x35 mm 2278x1134x35 mm 2094x1038x35 mm vs 2278x1134x35 mm
Module area 2.174 m² 2.583 m² 0.410 m² apart
Weight 24.1 kg 32.3 kg -8.2 kg for BF26-445W
Weight per kWp 54.2 kg/kWp 59.3 kg/kWp -5.1 kg/kWp for BF26-445W
Warranty and degradation
Product warranty 30 yrs 30 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.54 %/yr 0.54 %/yr Same
Technology
Cell technology PERC PERC Same
Cell type Monocrystalline Monocrystalline Same
Cell count 144 144 Same
Bifacial Yes Yes Same
04

Against the whole database

14,129 panels
Efficiency
#11,603 vs #9,587
BF10-545W-DG leads by 2,016 places
Power density
#11,558 vs #9,380
BF10-545W-DG leads by 2,178 places
Heat behaviour
#8,376 vs #8,821
BF26-445W leads by 445 places
Weight
#8,446 vs #12,183
BF26-445W leads by 3,737 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#7,912 vs #3,698
BF10-545W-DG leads by 4,214 places
05

More useful comparisons

Open the full database
Same series, other bin
Aptos Solar
Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-144-BF10-550W-DG
11 differences, the largest is module efficiency
Same series, other bin
Aptos Solar
Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-144-BF10-540W-DG
11 differences, the largest is rated power
Same series, other bin
Aptos Solar
Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-144-BF26-450W
One difference: module efficiency
Same series, other bin
Aptos Solar
Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-144-BF26-440W
One difference: module efficiency
Same manufacturer
Aptos Solar
Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-120-MF10-460W
10 differences, the largest is module efficiency
Same manufacturer
Aptos Solar
Aptos Solar DNA-144-BF26-445W vs Aptos Solar DNA-120-BF10-460W
12 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Aptos Solar DNA-144-BF26-445W or Aptos Solar DNA-144-BF10-545W-DG?
According to our database: Aptos Solar DNA-144-BF10-545 W-DG has higher module efficiency (21.09% vs 20.47%); Aptos Solar DNA-144-BF26-445 W tolerates heat better (temp coeff -0.320%/°C vs -0.335%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Aptos Solar DNA-144-BF26-445W and Aptos Solar DNA-144-BF10-545W-DG?
Aptos Solar DNA-144-BF26-445 W has a module efficiency of 20.47%, while Aptos Solar DNA-144-BF10-545 W-DG is 21.09%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Aptos Solar DNA-144-BF26-445W use vs Aptos Solar DNA-144-BF10-545W-DG?
Aptos Solar DNA-144-BF26-445 W uses PERC cells; Aptos Solar DNA-144-BF10-545 W-DG uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Aptos Solar DNA-144-BF26-445W and Aptos Solar DNA-144-BF10-545W-DG?
Aptos Solar DNA-144-BF26-445 W has a 30 years power warranty; Aptos Solar DNA-144-BF10-545 W-DG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Aptos Solar DNA-144-BF26-445W and Aptos Solar DNA-144-BF10-545W-DG bifacial panels?
Both Aptos Solar DNA-144-BF26-445 W and Aptos Solar DNA-144-BF10-545 W-DG are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 8 Aptos Solar offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.