AIKO M530M-144 vs AIKO M545M-144
VS
The verdict
M545M-144 leads on the differences that matter
The largest is module efficiency: 0.60 pp more efficient. 16 of 19 comparable parameters are identical.
See all 3 differencesHow alike are they
16
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
3 of 19 parameters
What actually differs
Parameter
M530M-144
M545M-144
Difference
Module efficiency
20.50 %
21.10 %
0.60 pp more efficient
Power density
205.1 Wp/m²
210.9 Wp/m²
5.8 Wp/m² higher
Rated power
530 Wp
545 Wp
15 W more power
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.360 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
M530M-144
17,177 kWh
M545M-144
17,663 kWh
Lifetime gap
486 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
M530M-144
M545M-144
Standard test conditions
25 °C
100.0% of rated power
530 W
545 W
Cool, bright day
40 °C
94.6% of rated power
501 W
516 W
Typical summer roof
55 °C
89.2% of rated power
473 W
486 W
Hot roof
70 °C
83.8% of rated power
444 W
457 W
03
Full specification
Parameter
M530M-144
M545M-144
Difference
Power and efficiency
Rated power
530 Wp
545 Wp
+15 W for M545M-144
Module efficiency
20.50 %
21.10 %
+0.60 pp for M545M-144
Power density
205.1 Wp/m²
210.9 Wp/m²
+5.8 Wp/m² for M545M-144
Open-circuit voltage
49.50 V
49.80 V
Effectively the same
Voltage at max power
41.70 V
42.00 V
Effectively the same
Short-circuit current
13.44 A
13.71 A
Effectively the same
Current at max power
12.71 A
12.98 A
Effectively the same
Temperature
Temperature coefficient
-0.360 %/°C
-0.360 %/°C
Same
Mechanical
Dimensions
2279x1134x35 mm
2279x1134x35 mm
Same
Module area
2.584 m²
2.584 m²
Same
Weight
29.0 kg
29.0 kg
Same
Weight per kWp
54.7 kg/kWp
53.2 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
12 yrs
12 yrs
Same
Performance warranty
25 yrs
25 yrs
Same
Annual degradation
0.55 %/yr
0.55 %/yr
Same
Technology
Cell technology
PERC
PERC
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
144
144
Same
Bifacial
No
No
Same
04
14,129 panels
Against the whole database
Efficiency
#11,389
vs
#9,365
M545M-144 leads by 2,024 places
Power density
#11,402
vs
#9,467
M545M-144 leads by 1,935 places
Heat behaviour
#12,425
vs
#12,425
Tied - the same position in the database
Weight
#9,198
vs
#7,112
M545M-144 leads by 2,086 places
Warranty
#9,912
vs
#9,912
Tied - the same position in the database
Overall
#9,717
vs
#8,616
M545M-144 leads by 1,101 places
05
Open the full database
More useful comparisons
Same series, other bin
AIKO M530M-144 vs AIKO M550M-144
3 differences, the largest is module efficiency
Same series, other bin
AIKO M530M-144 vs AIKO M540M-144
3 differences, the largest is module efficiency
Same series, other bin
AIKO M530M-144 vs AIKO M535M-144
One difference: module efficiency
Same manufacturer
AIKO M530M-144 vs AIKO AIKO-A805-GRH78Dw
17 differences, the largest is module efficiency
Same manufacturer
AIKO M530M-144 vs AIKO AIKO-A800-GRH78Dw
17 differences, the largest is module efficiency
Same manufacturer
AIKO M530M-144 vs AIKO AIKO-A795-GRH78Dw
17 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: AIKO M530M-144 or AIKO M545M-144?
According to our database: AIKO M545M-144 has higher module efficiency (21.10% vs 20.50%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AIKO M530M-144 and AIKO M545M-144?
AIKO M530M-144 has a module efficiency of 20.50%, while AIKO M545M-144 is 21.10%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AIKO M530M-144 use vs AIKO M545M-144?
AIKO M530M-144 uses PERC cells; AIKO M545M-144 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AIKO M530M-144 and AIKO M545M-144?
AIKO M530M-144 has a 25 years power warranty; AIKO M545M-144 has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Shop prices: See 137 AIKO offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.