Skip to main content
AIKO-A700-MAE78Dw vs JT755SLk(B) 4 of 19 identical Swap Change panels

AIKO AIKO-A700-MAE78Dw vs Jetion JT755SLk(B)

AIKO AIKO-A700-MAE78Dw
AIKO-A700-MAE78Dw
700 Wp 25.00 % Back Contact
VS
Jetion JT755SLk(B)
Jetion
JT755SLk(B)
755 Wp 24.30 % HJT Bifacial
The verdict

15 differences, and they point both ways

The largest is module efficiency: 0.70 pp more efficient. 4 of 19 comparable parameters are identical.

See all 15 differences
How alike are they
4 of 19 comparable
parameters are identical
identical differs
01

What actually differs

15 of 19 parameters
Parameter AIKO-A700-MAE78Dw JT755SLk(B) Difference
Module efficiency 25.00 % 24.30 % 0.70 pp more efficient
Rated power 700 Wp 755 Wp 55 W more power
Temperature coefficient -0.260 %/°C -0.240 %/°C 0.020 %/°C better in heat
Power density 250.4 Wp/m² 243.1 Wp/m² 7.4 Wp/m² higher
Open-circuit voltage 59.28 V 50.75 V 8.53 V apart
Short-circuit current 14.84 A 18.80 A 3.96 A apart
Module area 2.795 m² 3.106 m² 0.311 m² apart
Weight 34.5 kg 36.4 kg 1.9 kg lighter
Cell technology Back Contact HJT Back Contact vs HJT
Voltage at max power 49.15 V 42.76 V 6.39 V apart
Current at max power 14.25 A 17.66 A 3.41 A apart
Cell count 156 132 24 cells apart
Annual degradation 0.35 %/yr 0.30 %/yr 0.05 %/yr slower
Bifacial No Yes No vs Yes
Dimensions 2465x1134x30 mm 2384x1303x33 mm 2465x1134x30 mm vs 2384x1303x33 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
AIKO-A700-MAE78Dw
23,669 kWh
JT755SLk(B)
25,726 kWh
Lifetime gap
2,057 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario AIKO-A700-MAE78Dw JT755SLk(B)
Standard test conditions 25 °C 100.0% of rated power 700 W 755 W
Cool, bright day 40 °C 96.1% of rated power 673 W 728 W
Typical summer roof 55 °C 92.2% of rated power 645 W 701 W
Hot roof 70 °C 88.3% of rated power 618 W 673 W
03

Full specification

Parameter AIKO-A700-MAE78Dw JT755SLk(B) Difference
Power and efficiency
Rated power 700 Wp 755 Wp +55 W for JT755SLk(B)
Module efficiency 25.00 % 24.30 % +0.70 pp for AIKO-A700-MAE78Dw
Power density 250.4 Wp/m² 243.1 Wp/m² +7.4 Wp/m² for AIKO-A700-MAE78Dw
Open-circuit voltage 59.28 V 50.75 V 8.53 V apart
Voltage at max power 49.15 V 42.76 V 6.39 V apart
Short-circuit current 14.84 A 18.80 A 3.96 A apart
Current at max power 14.25 A 17.66 A 3.41 A apart
Temperature
Temperature coefficient -0.260 %/°C -0.240 %/°C +0.020 %/°C for JT755SLk(B)
Mechanical
Dimensions 2465x1134x30 mm 2384x1303x33 mm 2465x1134x30 mm vs 2384x1303x33 mm
Module area 2.795 m² 3.106 m² 0.311 m² apart
Weight 34.5 kg 36.4 kg -1.9 kg for AIKO-A700-MAE78Dw
Weight per kWp 49.3 kg/kWp 48.2 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.35 %/yr 0.30 %/yr -0.05 %/yr for JT755SLk(B)
Technology
Cell technology Back Contact HJT Back Contact vs HJT
Cell type Monocrystalline Monocrystalline Same
Cell count 156 132 24 cells apart
Bifacial No Yes No vs Yes
04

Against the whole database

14,005 panels
Efficiency
#4 vs #131
AIKO-A700-MAE78Dw leads by 127 places
Power density
#4 vs #136
AIKO-A700-MAE78Dw leads by 132 places
Heat behaviour
#511 vs #13
JT755SLk(B) leads by 498 places
Weight
#2,850 vs #2,105
JT755SLk(B) leads by 745 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#126 vs #50
JT755SLk(B) leads by 76 places
05

More useful comparisons

Open the full database
Same series, other bin
AIKO AIKO-A700-MAE78Dw vs AIKO AIKO-A695-MAE78Dw
The same specification on paper
Same series, other bin
AIKO AIKO-A700-MAE78Dw vs AIKO AIKO-A690-MAE78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A700-MAE78Dw vs AIKO AIKO-A685-MAE78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A700-MAE78Dw vs AIKO AIKO-A680-MAE78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A700-MAE78Dw vs AIKO AIKO-A675-MAE78Dw
3 differences, the largest is module efficiency
Same series, other bin
Jetion
Jetion JT755SLk(B) vs Jetion JT750SLk(B)
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: AIKO AIKO-A700-MAE78Dw or Jetion JT755SLk(B)?
According to our database: AIKO AIKO-A700-MAE78Dw has higher module efficiency (25.00% vs 24.30%); Jetion JT755SLk(B) tolerates heat better (temp coeff -0.240%/°C vs -0.260%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AIKO AIKO-A700-MAE78Dw and Jetion JT755SLk(B)?
AIKO AIKO-A700-MAE78Dw has a module efficiency of 25.00%, while Jetion JT755SLk(B) is 24.30%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AIKO AIKO-A700-MAE78Dw use vs Jetion JT755SLk(B)?
AIKO AIKO-A700-MAE78Dw uses Back Contact cells; Jetion JT755SLk(B) uses HJT. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AIKO AIKO-A700-MAE78Dw and Jetion JT755SLk(B)?
AIKO AIKO-A700-MAE78Dw has a 30 years power warranty; Jetion JT755SLk(B) has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AIKO AIKO-A700-MAE78Dw and Jetion JT755SLk(B) bifacial panels?
Jetion JT755SLk(B) is bifacial (captures light from both faces); AIKO AIKO-A700-MAE78Dw is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Compare AIKO and Jetion as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 174 AIKO offers · See 2 Jetion offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.