AE Solar AE MD-120 440W-460W (Pmax 440W class) vs AE Solar AE MD-120BD-460
VS
The verdict
120BD-460 leads on the differences that matter
The largest is module efficiency: 0.93 pp more efficient. 11 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 7 differencesHow alike are they
11
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 18 parameters
What actually differs
Parameter
120 440W-460W (Pmax 440W class)
120BD-460
Difference
Module efficiency
20.42 %
21.35 %
0.93 pp more efficient
Power density
204.2 Wp/m²
213.5 Wp/m²
9.3 Wp/m² higher
Weight
22.5 kg
25.5 kg
3.0 kg lighter
Rated power
440 Wp
460 Wp
20 W more power
Weight per kWp
51.1 kg/kWp
55.4 kg/kWp
4.3 kg/kWp lighter
Bifacial
No
Yes
No vs Yes
Open-circuit voltage
41.35 V
42.60 V
1.25 V apart
02
What it means on a roof
Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.350 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
120 440W-460W (Pmax 440W class)
14,525 kWh
120BD-460
15,186 kWh
Lifetime gap
661 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
120 440W-460W (Pmax 440W class)
120BD-460
Standard test conditions
25 °C
100.0% of rated power
440 W
460 W
Cool, bright day
40 °C
94.8% of rated power
417 W
436 W
Typical summer roof
55 °C
89.5% of rated power
394 W
412 W
Hot roof
70 °C
84.2% of rated power
371 W
388 W
03
Full specification
Parameter
120 440W-460W (Pmax 440W class)
120BD-460
Difference
Power and efficiency
Rated power
440 Wp
460 Wp
+20 W for 120BD-460
Module efficiency
20.42 %
21.35 %
+0.93 pp for 120BD-460
Power density
204.2 Wp/m²
213.5 Wp/m²
+9.3 Wp/m² for 120BD-460
Open-circuit voltage
41.35 V
42.60 V
1.25 V apart
Voltage at max power
34.62 V
35.60 V
Effectively the same
Short-circuit current
13.47 A
13.67 A
Effectively the same
Current at max power
12.71 A
12.92 A
Effectively the same
Temperature
Temperature coefficient
-0.350 %/°C
-0.350 %/°C
Same
Mechanical
Dimensions
1902x1133x30 mm
1902x1133x30 mm
Same
Module area
2.155 m²
2.155 m²
Same
Weight
22.5 kg
25.5 kg
-3.0 kg for 120 440W-460W (Pmax 440W class)
Weight per kWp
51.1 kg/kWp
55.4 kg/kWp
-4.3 kg/kWp for 120 440W-460W (Pmax 440W class)
Warranty and degradation
Product warranty
30 yrs
30 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
-
0.55 %/yr
Not published by AE Solar
Technology
Cell technology
PERC
PERC
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
120
120
Same
Bifacial
No
Yes
No vs Yes
04
14,129 panels
Against the whole database
Efficiency
#11,656
vs
#8,528
120BD-460 leads by 3,128 places
Power density
#11,667
vs
#8,487
120BD-460 leads by 3,180 places
Heat behaviour
#10,489
vs
#10,489
Tied - the same position in the database
Weight
#4,509
vs
#9,940
120 440W-460W (Pmax 440W class) leads by 5,431 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#8,080
vs
#6,272
120BD-460 leads by 1,808 places
05
Open the full database
More useful comparisons
Same series, other bin
AE Solar AE MD-120 440W-460W (Pmax 440W class) vs AE Solar MD-120BD-460
8 differences, the largest is module efficiency
Same series, other bin
AE Solar AE MD-120 440W-460W (Pmax 440W class) vs AE Solar AE MD-120 440W-460W (Pmax 460W class)
5 differences, the largest is module efficiency
Same series, other bin
AE Solar AE MD-120 440W-460W (Pmax 440W class) vs AE Solar MD-120BS-460
6 differences, the largest is module efficiency
Same series, other bin
AE Solar AE MD-120 440W-460W (Pmax 440W class) vs AE Solar MD-120E-460
5 differences, the largest is module efficiency
Same series, other bin
AE Solar AE MD-120 440W-460W (Pmax 440W class) vs AE Solar AE MD-120BS-460
6 differences, the largest is module efficiency
Same series, other bin
AE Solar AE MD-120 440W-460W (Pmax 440W class) vs AE Solar AE MD-120 460W
6 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: AE Solar AE MD-120 440W-460W (Pmax 440W class) or AE Solar AE MD-120BD-460?
According to our database: AE Solar AE MD-120BD-460 has higher module efficiency (21.35% vs 20.42%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AE Solar AE MD-120 440W-460W (Pmax 440W class) and AE Solar AE MD-120BD-460?
AE Solar AE MD-120 440 W-460 W (Pmax 440 W class) has a module efficiency of 20.42%, while AE Solar AE MD-120BD-460 is 21.35%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AE Solar AE MD-120 440W-460W (Pmax 440W class) use vs AE Solar AE MD-120BD-460?
AE Solar AE MD-120 440 W-460 W (Pmax 440 W class) uses PERC cells; AE Solar AE MD-120BD-460 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AE Solar AE MD-120 440W-460W (Pmax 440W class) and AE Solar AE MD-120BD-460?
AE Solar AE MD-120 440 W-460 W (Pmax 440 W class) has a 30 years power warranty; AE Solar AE MD-120BD-460 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AE Solar AE MD-120 440W-460W (Pmax 440W class) and AE Solar AE MD-120BD-460 bifacial panels?
AE Solar AE MD-120BD-460 is bifacial (captures light from both faces); AE Solar AE MD-120 440 W-460 W (Pmax 440 W class) is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 4 AE Solar offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.