Skip to main content
SG7.0RT-P2 vs MIN 7000TL-X(E) 10 of 23 identical Swap Change inverters

Sungrow SG7.0RT-P2 vs Growatt MIN 7000TL-X(E)

Sungrow SG7.0RT-P2
Sungrow
SG7.0RT-P2
7 kW 97.6 % euro Grid-tie
VS
Growatt MIN 7000TL-X(E)
Growatt
MIN 7000TL-X(E)
7 kW 97.3 % euro Grid-tie
The verdict

SG7.0RT-P2 leads on the differences that matter

The largest is max dc voltage: 500 V apart. 10 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
10 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 23 parameters
Parameter SG7.0RT-P2 MIN 7000TL-X(E) Difference
Max DC voltage 1100 V 600 V 500 V apart
Max input current per tracker 32.0 A 27.0 A 5.0 A more headroom
Max PV power 10.50 kW 12.00 kW 1.50 kW apart
DC/AC ratio 1.50 1.71 0.21 more oversizing headroom
European efficiency 97.6 % 97.3 % 0.3 pp more efficient
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 11.7 A 33.5 A 21.8 A apart
Start voltage 180 V 100 V 80 V earlier start
Max efficiency 98.3 % 98.1 % 0.2 pp more efficient
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 160-1000 V 60-550 V 160-1000 V vs 60-550 V
Dimensions 480x370x195 mm 387x425x180 mm 480x370x195 mm vs 387x425x180 mm
02

Full specification

Parameter SG7.0RT-P2 MIN 7000TL-X(E) Difference
AC output
Rated AC power 7.00 kW 7.00 kW Same
Max AC power 7.00 kW 7.00 kW Same
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 11.7 A 33.5 A 21.8 A apart
PV input
Max PV power 10.50 kW 12.00 kW 1.50 kW apart
DC/AC ratio 1.50 1.71 +0.21 for MIN 7000TL-X(E)
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 160-1000 V 60-550 V 160-1000 V vs 60-550 V
Start voltage 180 V 100 V -80 V for MIN 7000TL-X(E)
MPP trackers 2 - Not published by Growatt
Strings per tracker 1 - Not published by Growatt
Max input current per tracker 32.0 A 27.0 A +5.0 A for SG7.0RT-P2
Efficiency
European efficiency 97.6 % 97.3 % +0.3 pp for SG7.0RT-P2
Max efficiency 98.3 % 98.1 % +0.2 pp for SG7.0RT-P2
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 18.0 kg 18.2 kg Effectively the same
Weight per kW 2.6 kg/kW 2.6 kg/kW Same
Dimensions 480x370x195 mm 387x425x180 mm 480x370x195 mm vs 387x425x180 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Sungrow
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Sungrow SG7.0RT-P2 vs Growatt MOD 7000TL3-X
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Sungrow SG7.0RT-P2 vs Growatt MOD 7KTL3-X2(Pro)
9 differences, the largest is european efficiency
Same type, similar size
Sungrow
Sungrow SG7.0RT-P2 vs Sungrow SG5.0RT
4 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.