Sungrow SG60KTL-182 vs SOFAR 60000TL
VS
The verdict
SG60KTL-182 leads on the differences that matter
The largest is max input current per tracker: 80.0 A more headroom. 9 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 19 parameters
What actually differs
Parameter
SG60KTL-182
SOFAR 60000TL
Difference
Max input current per tracker
120.0 A
40.0 A
80.0 A more headroom
Max AC power
66.00 kW
60.00 kW
6.00 kW apart
MPP trackers
1
3
2 trackers more
Weight
60.0 kg
70.0 kg
10.0 kg lighter
European efficiency
98.7 %
98.4 %
0.3 pp more efficient
Max efficiency
98.9 %
98.6 %
0.3 pp more efficient
Max AC current
96.0 A
90.0 A
6.0 A apart
Start voltage
620 V
350 V
270 V earlier start
MPPT voltage range
570-950 V
250-950 V
570-950 V vs 250-950 V
Dimensions
959x634x267 mm
737x713x297 mm
959x634x267 mm vs 737x713x297 mm
02
Full specification
Parameter
SG60KTL-182
SOFAR 60000TL
Difference
AC output
Rated AC power
60.00 kW
60.00 kW
Same
Max AC power
66.00 kW
60.00 kW
6.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
96.0 A
90.0 A
6.0 A apart
PV input
Max PV power
-
79.80 kW
Not published by Sungrow
DC/AC ratio
-
1.33
Not published by Sungrow
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
570-950 V
250-950 V
570-950 V vs 250-950 V
Start voltage
620 V
350 V
-270 V for SOFAR 60000TL
MPP trackers
1
3
+2 trackers for SOFAR 60000TL
Strings per tracker
14
-
Not published by Sofar Solar
Max input current per tracker
120.0 A
40.0 A
+80.0 A for SG60KTL-182
Efficiency
European efficiency
98.7 %
98.4 %
+0.3 pp for SG60KTL-182
Max efficiency
98.9 %
98.6 %
+0.3 pp for SG60KTL-182
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
60.0 kg
70.0 kg
-10.0 kg for SG60KTL-182
Weight per kW
1.0 kg/kW
1.2 kg/kW
Effectively the same
Dimensions
959x634x267 mm
737x713x297 mm
959x634x267 mm vs 737x713x297 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
60 dB
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Sungrow SG60KTL-182 vs Huawei SUN2000-60KTL-M0
12 differences, the largest is mpp trackers
Same type, similar size
GoodWe
Sungrow SG60KTL-182 vs GoodWe GW60KN-MT
9 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Sungrow SG60KTL-182 vs Solis-60K-4G
10 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.