Sungrow SG60KTL-182 vs SMA Solar Sunny Tripower X 60 (STP 60-80)
VS

SMA Solar
Sunny Tripower X 60 (STP 60-80)
60 kW
97.8 % euro
Grid-tie
The verdict
SG60KTL-182 leads on the differences that matter
The largest is european efficiency: 0.9 pp more efficient. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
SG60KTL-182
Sunny Tripower X 60 (STP 60-80)
Difference
European efficiency
98.7 %
97.8 %
0.9 pp more efficient
MPP trackers
1
5
4 trackers more
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
120.0 A
40.0 A
80.0 A more headroom
Max efficiency
98.9 %
98.1 %
0.8 pp more efficient
Max AC power
66.00 kW
60.00 kW
6.00 kW apart
Weight
60.0 kg
50.5 kg
9.5 kg lighter
Start voltage
620 V
250 V
370 V earlier start
Strings per tracker
14
2
12 strings apart
MPPT voltage range
570-950 V
200-1000 V
570-950 V vs 200-1000 V
Max AC current
96.0 A
95.3 A
0.7 A apart
Dimensions
959x634x267 mm
718x680x332 mm
959x634x267 mm vs 718x680x332 mm
02
Full specification
Parameter
SG60KTL-182
Sunny Tripower X 60 (STP 60-80)
Difference
AC output
Rated AC power
60.00 kW
60.00 kW
Same
Max AC power
66.00 kW
60.00 kW
6.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
96.0 A
95.3 A
0.7 A apart
PV input
Max PV power
-
90.00 kW
Not published by Sungrow
DC/AC ratio
-
1.50
Not published by Sungrow
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
570-950 V
200-1000 V
570-950 V vs 200-1000 V
Start voltage
620 V
250 V
-370 V for Sunny Tripower X 60 (STP 60-80)
MPP trackers
1
5
+4 trackers for Sunny Tripower X 60 (STP 60-80)
Strings per tracker
14
2
12 strings apart
Max input current per tracker
120.0 A
40.0 A
+80.0 A for SG60KTL-182
Efficiency
European efficiency
98.7 %
97.8 %
+0.9 pp for SG60KTL-182
Max efficiency
98.9 %
98.1 %
+0.8 pp for SG60KTL-182
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
60.0 kg
50.5 kg
-9.5 kg for Sunny Tripower X 60 (STP 60-80)
Weight per kW
1.0 kg/kW
0.8 kg/kW
Effectively the same
Dimensions
959x634x267 mm
718x680x332 mm
959x634x267 mm vs 718x680x332 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
63 dB
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Sungrow SG60KTL-182 vs Huawei SUN2000-60KTL-M0
12 differences, the largest is mpp trackers
Same type, similar size
GoodWe
Sungrow SG60KTL-182 vs GoodWe GW60KN-MT
9 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Sungrow SG60KTL-182 vs Solis-60K-4G
10 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.