SG60KTL-182 vs S6-GC3P60K05-NV-ND 6 of 19 identical Swap Change inverters

Sungrow SG60KTL-182 vs Ginlong Solis S6-GC3P60K05-NV-ND

Sungrow
SG60KTL-182
60 kW 98.7 % euro Grid-tie
VS
Ginlong Solis S6-GC3P60K05-NV-ND
Ginlong Solis
S6-GC3P60K05-NV-ND
60 kW 98.1 % euro Grid-tie
The verdict

SG60KTL-182 leads on the differences that matter

The largest is european efficiency: 0.6 pp more efficient. 6 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 19 parameters
Parameter SG60KTL-182 S6-GC3P60K05-NV-ND Difference
European efficiency 98.7 % 98.1 % 0.6 pp more efficient
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 120.0 A 40.0 A 80.0 A more headroom
Max AC power 66.00 kW 60.00 kW 6.00 kW apart
Weight 60.0 kg 38.6 kg 21.4 kg lighter
Max efficiency 98.9 % 98.6 % 0.3 pp more efficient
Max AC current 96.0 A 91.2 A 4.8 A apart
Start voltage 620 V 180 V 440 V earlier start
Strings per tracker 14 2 12 strings apart
Weight per kW 1.0 kg/kW 0.6 kg/kW 0.4 kg/kW lighter
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 570-950 V 180-1000 V 570-950 V vs 180-1000 V
Dimensions 959x634x267 mm 672x515x288 mm 959x634x267 mm vs 672x515x288 mm
02

Full specification

Parameter SG60KTL-182 S6-GC3P60K05-NV-ND Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 60.00 kW 6.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 96.0 A 91.2 A 4.8 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 570-950 V 180-1000 V 570-950 V vs 180-1000 V
Start voltage 620 V 180 V -440 V for S6-GC3P60K05-NV-ND
MPP trackers 1 - Not published by Ginlong Solis
Strings per tracker 14 2 12 strings apart
Max input current per tracker 120.0 A 40.0 A +80.0 A for SG60KTL-182
Efficiency
European efficiency 98.7 % 98.1 % +0.6 pp for SG60KTL-182
Max efficiency 98.9 % 98.6 % +0.3 pp for SG60KTL-182
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 60.0 kg 38.6 kg -21.4 kg for S6-GC3P60K05-NV-ND
Weight per kW 1.0 kg/kW 0.6 kg/kW -0.4 kg/kW for S6-GC3P60K05-NV-ND
Dimensions 959x634x267 mm 672x515x288 mm 959x634x267 mm vs 672x515x288 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - 60 dB Not published by Sungrow
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Sungrow
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Sungrow
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Sungrow SG60KTL-182 vs Huawei SUN2000-60KTL-M0
12 differences, the largest is mpp trackers
Same type, similar size
GoodWe
Sungrow SG60KTL-182 vs GoodWe GW60KN-MT
9 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Sungrow SG60KTL-182 vs Solis-60K-4G
10 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.