SG60KTL-182 vs S5-GC60K 8 of 19 identical Swap Change inverters

Sungrow SG60KTL-182 vs Ginlong Solis S5-GC60K

Sungrow
SG60KTL-182
60 kW 98.7 % euro Grid-tie
VS
Ginlong Solis S5-GC60K
Ginlong Solis
S5-GC60K
60 kW 98.3 % euro Grid-tie
The verdict

SG60KTL-182 leads on the differences that matter

The largest is max dc voltage: 100 V apart. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 19 parameters
Parameter SG60KTL-182 S5-GC60K Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 120.0 A 32.0 A 88.0 A more headroom
European efficiency 98.7 % 98.3 % 0.4 pp more efficient
Weight 60.0 kg 53.7 kg 6.3 kg lighter
Max AC current 96.0 A 100.3 A 4.3 A apart
Start voltage 620 V 195 V 425 V earlier start
Strings per tracker 14 2 12 strings apart
Max efficiency 98.9 % 98.7 % 0.2 pp more efficient
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 570-950 V 180-1000 V 570-950 V vs 180-1000 V
Dimensions 959x634x267 mm 578x691x338 mm 959x634x267 mm vs 578x691x338 mm
02

Full specification

Parameter SG60KTL-182 S5-GC60K Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 66.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 96.0 A 100.3 A 4.3 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 570-950 V 180-1000 V 570-950 V vs 180-1000 V
Start voltage 620 V 195 V -425 V for S5-GC60K
MPP trackers 1 - Not published by Ginlong Solis
Strings per tracker 14 2 12 strings apart
Max input current per tracker 120.0 A 32.0 A +88.0 A for SG60KTL-182
Efficiency
European efficiency 98.7 % 98.3 % +0.4 pp for SG60KTL-182
Max efficiency 98.9 % 98.7 % +0.2 pp for SG60KTL-182
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 60.0 kg 53.7 kg -6.3 kg for S5-GC60K
Weight per kW 1.0 kg/kW 0.9 kg/kW Effectively the same
Dimensions 959x634x267 mm 578x691x338 mm 959x634x267 mm vs 578x691x338 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - 55 dB Not published by Sungrow
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Sungrow
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Sungrow SG60KTL-182 vs Huawei SUN2000-60KTL-M0
12 differences, the largest is mpp trackers
Same type, similar size
GoodWe
Sungrow SG60KTL-182 vs GoodWe GW60KN-MT
9 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Sungrow SG60KTL-182 vs Solis-60K-4G
10 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.