Sungrow SG40CX-P2 vs Deye SUN-40K-G-LV
VS
The verdict
15 differences, and they point both ways
The largest is max dc voltage: 300 V apart. 9 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
9
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 24 parameters
What actually differs
Parameter
SG40CX-P2
SUN-40K-G-LV
Difference
Max DC voltage
1100 V
800 V
300 V apart
Max input current per tracker
30.0 A
40.0 A
10.0 A more headroom
Max PV power
56.00 kW
52.00 kW
4.00 kW apart
Weight
40.0 kg
60.0 kg
20.0 kg lighter
Weight per kW
1.0 kg/kW
1.5 kg/kW
0.5 kg/kW lighter
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
66.9 A
115.5 A
48.6 A apart
Start voltage
200 V
250 V
50 V earlier start
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
DC/AC ratio
1.40
1.30
0.10 more oversizing headroom
Max efficiency
98.5 %
98.7 %
0.2 pp more efficient
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
160-1000 V
200-700 V
160-1000 V vs 200-700 V
Strings per tracker
2
1
1 string apart
Dimensions
575x645x245 mm
575x700x297 mm
575x645x245 mm vs 575x700x297 mm
02
Full specification
Parameter
SG40CX-P2
SUN-40K-G-LV
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
44.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
66.9 A
115.5 A
48.6 A apart
PV input
Max PV power
56.00 kW
52.00 kW
4.00 kW apart
DC/AC ratio
1.40
1.30
+0.10 for SG40CX-P2
Max DC voltage
1100 V
800 V
300 V apart
MPPT voltage range
160-1000 V
200-700 V
160-1000 V vs 200-700 V
Start voltage
200 V
250 V
-50 V for SG40CX-P2
MPP trackers
4
4
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
30.0 A
40.0 A
+10.0 A for SUN-40K-G-LV
Efficiency
European efficiency
98.3 %
98.3 %
Same
Max efficiency
98.5 %
98.7 %
+0.2 pp for SUN-40K-G-LV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
40.0 kg
60.0 kg
-20.0 kg for SG40CX-P2
Weight per kW
1.0 kg/kW
1.5 kg/kW
-0.5 kg/kW for SG40CX-P2
Dimensions
575x645x245 mm
575x700x297 mm
575x645x245 mm vs 575x700x297 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
55 dB
Not published by Sungrow
Max operating temperature
60 °C
65 °C
+5 °C for SUN-40K-G-LV
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG40CX-P2 vs Growatt MID 40KTL3-X
10 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Sungrow SG40CX-P2 vs Huawei SUN2000-40KTL-M3
8 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Sungrow SG40CX-P2 vs Solis-40K
8 differences, the largest is max pv power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.