Skip to main content
SG36CX-P2 vs MID 36KTL3-X 13 of 24 identical Swap Change inverters

Sungrow SG36CX-P2 vs Growatt MID 36KTL3-X

Sungrow SG36CX-P2
Sungrow
SG36CX-P2
36 kW 98.3 % euro Grid-tie
VS
Growatt MID 36KTL3-X
Growatt
MID 36KTL3-X
36 kW 98.5 % euro Grid-tie
The verdict

MID 36KTL3-X leads on the differences that matter

The largest is max input current per tracker: 4.0 A more headroom. 13 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
13 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 24 parameters
Parameter SG36CX-P2 MID 36KTL3-X Difference
Max input current per tracker 30.0 A 26.0 A 4.0 A more headroom
Max AC power 40.00 kW 39.60 kW 0.40 kW apart
Max PV power 50.40 kW 54.00 kW 3.60 kW apart
Weight 40.0 kg 30.5 kg 9.5 kg lighter
European efficiency 98.3 % 98.5 % 0.2 pp more efficient
Max efficiency 98.5 % 98.8 % 0.3 pp more efficient
DC/AC ratio 1.40 1.50 0.10 more oversizing headroom
Start voltage 200 V 250 V 50 V earlier start
Weight per kW 1.1 kg/kW 0.8 kg/kW 0.3 kg/kW lighter
MPPT voltage range 160-1000 V 200-1000 V 160-1000 V vs 200-1000 V
Dimensions 575x645x245 mm 435x580x230 mm 575x645x245 mm vs 435x580x230 mm
02

Full specification

Parameter SG36CX-P2 MID 36KTL3-X Difference
AC output
Rated AC power 36.00 kW 36.00 kW Same
Max AC power 40.00 kW 39.60 kW 0.40 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 60.2 A 60.0 A Effectively the same
PV input
Max PV power 50.40 kW 54.00 kW 3.60 kW apart
DC/AC ratio 1.40 1.50 +0.10 for MID 36KTL3-X
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 160-1000 V 200-1000 V 160-1000 V vs 200-1000 V
Start voltage 200 V 250 V -50 V for SG36CX-P2
MPP trackers 4 - Not published by Growatt
Strings per tracker 2 2 Same
Max input current per tracker 30.0 A 26.0 A +4.0 A for SG36CX-P2
Efficiency
European efficiency 98.3 % 98.5 % +0.2 pp for MID 36KTL3-X
Max efficiency 98.5 % 98.8 % +0.3 pp for MID 36KTL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 40.0 kg 30.5 kg -9.5 kg for MID 36KTL3-X
Weight per kW 1.1 kg/kW 0.8 kg/kW -0.3 kg/kW for MID 36KTL3-X
Dimensions 575x645x245 mm 435x580x230 mm 575x645x245 mm vs 435x580x230 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Sungrow
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Sungrow SG36CX-P2 vs GoodWe GW36K-MT
8 differences, the largest is max ac power
Same type, similar size
Huawei
Sungrow SG36CX-P2 vs Huawei SUN2000-36KTL
9 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Sungrow SG36CX-P2 vs Huawei SUN2000-36KTL-M3
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.