8 differences, and they point both ways
The largest is max input current per tracker: 29.0 A more headroom. 11 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
11
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 19 parameters
What actually differs
Parameter
SG33T-P2-CN
GW33K-SDT-CN-G40
Difference
Max input current per tracker
50.0 A
21.0 A
29.0 A more headroom
Weight
25.0 kg
19.0 kg
6.0 kg lighter
Noise
55 dB
45 dB
10 dB quieter
Nominal AC voltage
400 V
380 V
20 V apart
MPP trackers
3
2
1 tracker more
MPPT voltage range
160-1000 V
140-1000 V
160-1000 V vs 140-1000 V
Start voltage
180 V
160 V
20 V earlier start
Dimensions
466x615x225 mm
413x530x211 mm
466x615x225 mm vs 413x530x211 mm
02
Full specification
Parameter
SG33T-P2-CN
GW33K-SDT-CN-G40
Difference
AC output
Rated AC power
33.00 kW
33.00 kW
Same
Max AC power
36.30 kW
36.30 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
380 V
20 V apart
Max AC current
55.0 A
55.0 A
Same
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
160-1000 V
140-1000 V
160-1000 V vs 140-1000 V
Start voltage
180 V
160 V
-20 V for GW33K-SDT-CN-G40
MPP trackers
3
2
+1 trackers for SG33T-P2-CN
Strings per tracker
-
2
Not published by Sungrow
Max input current per tracker
50.0 A
21.0 A
+29.0 A for SG33T-P2-CN
Efficiency
European efficiency
98.3 %
-
Not published by GoodWe
Max efficiency
98.6 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
25.0 kg
19.0 kg
-6.0 kg for GW33K-SDT-CN-G40
Weight per kW
0.8 kg/kW
0.6 kg/kW
Effectively the same
Dimensions
466x615x225 mm
413x530x211 mm
466x615x225 mm vs 413x530x211 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
55 dB
45 dB
-10 dB for GW33K-SDT-CN-G40
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG33T-P2-CN vs Growatt MID 33KTL3-X
9 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Sungrow SG33T-P2-CN vs Sungrow SG33CX
6 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Sungrow SG33T-P2-CN vs Sungrow SG33CX-P2
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.