Sungrow SG33CX-P2 vs Deye SUN-33K-G03
VS
The verdict
15 differences, and they point both ways
The largest is max dc voltage: 100 V apart. 6 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
6
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 21 parameters
What actually differs
Parameter
SG33CX-P2
SUN-33K-G03
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
30.0 A
40.0 A
10.0 A more headroom
Max AC power
33.00 kW
36.30 kW
3.30 kW apart
Max PV power
46.20 kW
42.90 kW
3.30 kW apart
Weight
38.0 kg
44.5 kg
6.5 kg lighter
European efficiency
98.3 %
98.0 %
0.3 pp more efficient
Max AC current
55.2 A
52.8 A
2.4 A apart
Start voltage
200 V
250 V
50 V earlier start
MPP trackers
3
4
1 tracker more
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
DC/AC ratio
1.40
1.30
0.10 more oversizing headroom
Max efficiency
98.5 %
98.7 %
0.2 pp more efficient
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
160-1000 V
200-850 V
160-1000 V vs 200-850 V
Dimensions
575x645x245 mm
537x648x304 mm
575x645x245 mm vs 537x648x304 mm
02
Full specification
Parameter
SG33CX-P2
SUN-33K-G03
Difference
AC output
Rated AC power
33.00 kW
33.00 kW
Same
Max AC power
33.00 kW
36.30 kW
3.30 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
55.2 A
52.8 A
2.4 A apart
PV input
Max PV power
46.20 kW
42.90 kW
3.30 kW apart
DC/AC ratio
1.40
1.30
+0.10 for SG33CX-P2
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
160-1000 V
200-850 V
160-1000 V vs 200-850 V
Start voltage
200 V
250 V
-50 V for SG33CX-P2
MPP trackers
3
4
+1 trackers for SUN-33K-G03
Strings per tracker
2
-
Not published by Deye
Max input current per tracker
30.0 A
40.0 A
+10.0 A for SUN-33K-G03
Efficiency
European efficiency
98.3 %
98.0 %
+0.3 pp for SG33CX-P2
Max efficiency
98.5 %
98.7 %
+0.2 pp for SUN-33K-G03
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
38.0 kg
44.5 kg
-6.5 kg for SG33CX-P2
Weight per kW
1.2 kg/kW
1.3 kg/kW
Effectively the same
Dimensions
575x645x245 mm
537x648x304 mm
575x645x245 mm vs 537x648x304 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
45 dB
Not published by Sungrow
Max operating temperature
60 °C
65 °C
+5 °C for SUN-33K-G03
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG33CX-P2 vs Growatt MID 33KTL3-X
11 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Sungrow SG33CX-P2 vs Sungrow SG33CX
7 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Sungrow SG33CX-P2 vs Sungrow SG33T-P2-CN
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.