Sungrow SG20KTL-M vs Ginlong Solis S5-GC20K-LV
VS
The verdict
SG20KTL-M leads on the differences that matter
The largest is european efficiency: 1.0 pp more efficient. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
SG20KTL-M
S5-GC20K-LV
Difference
European efficiency
98.3 %
97.3 %
1.0 pp more efficient
Max input current per tracker
22.0 A
32.0 A
10.0 A more headroom
Max efficiency
98.6 %
97.8 %
0.8 pp more efficient
Max AC power
20.00 kW
22.00 kW
2.00 kW apart
Weight
24.0 kg
42.1 kg
18.1 kg lighter
Weight per kW
1.2 kg/kW
2.1 kg/kW
0.9 kg/kW lighter
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
31.9 A
57.7 A
25.8 A apart
Start voltage
250 V
180 V
70 V earlier start
MPP trackers
2
3
1 tracker more
Ingress protection
IP65
IP66
IP65 vs IP66
Dimensions
485x370x210 mm
629x647x252 mm
485x370x210 mm vs 629x647x252 mm
02
Full specification
Parameter
SG20KTL-M
S5-GC20K-LV
Difference
AC output
Rated AC power
20.00 kW
20.00 kW
Same
Max AC power
20.00 kW
22.00 kW
2.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
31.9 A
57.7 A
25.8 A apart
PV input
Max PV power
-
30.00 kW
Not published by Sungrow
DC/AC ratio
-
1.50
Not published by Sungrow
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
250 V
180 V
-70 V for S5-GC20K-LV
MPP trackers
2
3
+1 trackers for S5-GC20K-LV
Strings per tracker
2
2
Same
Max input current per tracker
22.0 A
32.0 A
+10.0 A for S5-GC20K-LV
Efficiency
European efficiency
98.3 %
97.3 %
+1.0 pp for SG20KTL-M
Max efficiency
98.6 %
97.8 %
+0.8 pp for SG20KTL-M
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
24.0 kg
42.1 kg
-18.1 kg for SG20KTL-M
Weight per kW
1.2 kg/kW
2.1 kg/kW
-0.9 kg/kW for SG20KTL-M
Dimensions
485x370x210 mm
629x647x252 mm
485x370x210 mm vs 629x647x252 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
-
60 dB
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG20KTL-M vs Growatt MID 20KTL3-X
4 differences, the largest is max ac power
Same type, similar size
Fronius International
Sungrow SG20KTL-M vs Fronius Verto 20.0
10 differences, the largest is max dc voltage
Same type, similar size
Huawei
Sungrow SG20KTL-M vs Huawei SUN2000-20KTL-M2
8 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.