Sungrow SG15KTL-M vs SOFAR 15KTLX-G3
VS
The verdict
SOFAR 15KTLX-G3 leads on the differences that matter
The largest is max input current per tracker: 4.0 A more headroom. 13 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
13
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 20 parameters
What actually differs
Parameter
SG15KTL-M
SOFAR 15KTLX-G3
Difference
Max input current per tracker
22.0 A
26.0 A
4.0 A more headroom
Weight
24.0 kg
20.0 kg
4.0 kg lighter
Start voltage
250 V
160 V
90 V earlier start
Weight per kW
1.6 kg/kW
1.3 kg/kW
0.3 kg/kW lighter
MPPT voltage range
200-1000 V
140-1000 V
200-1000 V vs 140-1000 V
Strings per tracker
2
1
1 string apart
Dimensions
485x370x210 mm
430x520x198 mm
485x370x210 mm vs 430x520x198 mm
02
Full specification
Parameter
SG15KTL-M
SOFAR 15KTLX-G3
Difference
AC output
Rated AC power
15.00 kW
15.00 kW
Same
Max AC power
15.00 kW
15.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
24.0 A
23.9 A
Effectively the same
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
140-1000 V
200-1000 V vs 140-1000 V
Start voltage
250 V
160 V
-90 V for SOFAR 15KTLX-G3
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
22.0 A
26.0 A
+4.0 A for SOFAR 15KTLX-G3
Efficiency
European efficiency
98.3 %
98.2 %
Effectively the same
Max efficiency
98.6 %
98.6 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
24.0 kg
20.0 kg
-4.0 kg for SOFAR 15KTLX-G3
Weight per kW
1.6 kg/kW
1.3 kg/kW
-0.3 kg/kW for SOFAR 15KTLX-G3
Dimensions
485x370x210 mm
430x520x198 mm
485x370x210 mm vs 430x520x198 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG15KTL-M vs Growatt MID 15KTL3-X
4 differences, the largest is max ac power
Same type, similar size
Huawei
Sungrow SG15KTL-M vs Huawei SUN2000-15KTL-M2
8 differences, the largest is max ac power
Same type, similar size
Huawei
Sungrow SG15KTL-M vs Huawei SUN2000-15KTL-M0
8 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.
