Skip to main content
SG15KTL-M vs SOFAR 15KTLX-G3 13 of 20 identical Swap Change inverters

Sungrow SG15KTL-M vs SOFAR 15KTLX-G3

Sungrow
SG15KTL-M
15 kW 98.3 % euro Grid-tie
VS
SOFAR 15KTLX-G3
Sofar Solar
SOFAR 15KTLX-G3
15 kW 98.2 % euro Grid-tie
The verdict

SOFAR 15KTLX-G3 leads on the differences that matter

The largest is max input current per tracker: 4.0 A more headroom. 13 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
13 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 20 parameters
Parameter SG15KTL-M SOFAR 15KTLX-G3 Difference
Max input current per tracker 22.0 A 26.0 A 4.0 A more headroom
Weight 24.0 kg 20.0 kg 4.0 kg lighter
Start voltage 250 V 160 V 90 V earlier start
Weight per kW 1.6 kg/kW 1.3 kg/kW 0.3 kg/kW lighter
MPPT voltage range 200-1000 V 140-1000 V 200-1000 V vs 140-1000 V
Strings per tracker 2 1 1 string apart
Dimensions 485x370x210 mm 430x520x198 mm 485x370x210 mm vs 430x520x198 mm
02

Full specification

Parameter SG15KTL-M SOFAR 15KTLX-G3 Difference
AC output
Rated AC power 15.00 kW 15.00 kW Same
Max AC power 15.00 kW 15.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 24.0 A 23.9 A Effectively the same
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 140-1000 V 200-1000 V vs 140-1000 V
Start voltage 250 V 160 V -90 V for SOFAR 15KTLX-G3
MPP trackers 2 2 Same
Strings per tracker 2 1 1 string apart
Max input current per tracker 22.0 A 26.0 A +4.0 A for SOFAR 15KTLX-G3
Efficiency
European efficiency 98.3 % 98.2 % Effectively the same
Max efficiency 98.6 % 98.6 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 24.0 kg 20.0 kg -4.0 kg for SOFAR 15KTLX-G3
Weight per kW 1.6 kg/kW 1.3 kg/kW -0.3 kg/kW for SOFAR 15KTLX-G3
Dimensions 485x370x210 mm 430x520x198 mm 485x370x210 mm vs 430x520x198 mm
Ingress protection IP65 IP65 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Sungrow
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Sungrow SG15KTL-M vs Growatt MID 15KTL3-X
4 differences, the largest is max ac power
Same type, similar size
Huawei
Sungrow SG15KTL-M vs Huawei SUN2000-15KTL-M2
8 differences, the largest is max ac power
Same type, similar size
Huawei
Sungrow SG15KTL-M vs Huawei SUN2000-15KTL-M0
8 differences, the largest is max ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.