Sungrow SG15KTL-M vs SMA Solar STP 15-50 (Sunny Tripower X 15)
VS

SMA Solar
STP 15-50 (Sunny Tripower X 15)
15 kW
97.8 % euro
Grid-tie
The verdict
SG15KTL-M leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
SG15KTL-M
STP 15-50 (Sunny Tripower X 15)
Difference
European efficiency
98.3 %
97.8 %
0.5 pp more efficient
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
22.0 A
24.0 A
2.0 A more headroom
Weight
24.0 kg
35.0 kg
11.0 kg lighter
Weight per kW
1.6 kg/kW
2.3 kg/kW
0.7 kg/kW lighter
Max efficiency
98.6 %
98.2 %
0.4 pp more efficient
Nominal AC voltage
400 V
230 V
170 V apart
Start voltage
250 V
188 V
62 V earlier start
MPP trackers
2
3
1 tracker more
Max AC current
24.0 A
25.0 A
1.0 A apart
MPPT voltage range
200-1000 V
150-1000 V
200-1000 V vs 150-1000 V
Dimensions
485x370x210 mm
762x728x266 mm
485x370x210 mm vs 762x728x266 mm
02
Full specification
Parameter
SG15KTL-M
STP 15-50 (Sunny Tripower X 15)
Difference
AC output
Rated AC power
15.00 kW
15.00 kW
Same
Max AC power
15.00 kW
15.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
24.0 A
25.0 A
1.0 A apart
PV input
Max PV power
-
22.50 kW
Not published by Sungrow
DC/AC ratio
-
1.50
Not published by Sungrow
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
200-1000 V
150-1000 V
200-1000 V vs 150-1000 V
Start voltage
250 V
188 V
-62 V for STP 15-50 (Sunny Tripower X 15)
MPP trackers
2
3
+1 trackers for STP 15-50 (Sunny Tripower X 15)
Strings per tracker
2
2
Same
Max input current per tracker
22.0 A
24.0 A
+2.0 A for STP 15-50 (Sunny Tripower X 15)
Efficiency
European efficiency
98.3 %
97.8 %
+0.5 pp for SG15KTL-M
Max efficiency
98.6 %
98.2 %
+0.4 pp for SG15KTL-M
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
24.0 kg
35.0 kg
-11.0 kg for SG15KTL-M
Weight per kW
1.6 kg/kW
2.3 kg/kW
-0.7 kg/kW for SG15KTL-M
Dimensions
485x370x210 mm
762x728x266 mm
485x370x210 mm vs 762x728x266 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
59 dB
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG15KTL-M vs Growatt MID 15KTL3-X
4 differences, the largest is max ac power
Same type, similar size
Huawei
Sungrow SG15KTL-M vs Huawei SUN2000-15KTL-M2
8 differences, the largest is max ac power
Same type, similar size
Huawei
Sungrow SG15KTL-M vs Huawei SUN2000-15KTL-M0
8 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.