Sungrow SG12RT-P2 vs Sungrow SG12KTL-M
VS
The verdict
SG12RT-P2 leads on the differences that matter
The largest is max input current per tracker: 21.0 A more headroom. 14 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
14
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 20 parameters
What actually differs
Parameter
SG12RT-P2
SG12KTL-M
Difference
Max input current per tracker
32.0 A
11.0 A
21.0 A more headroom
Weight
18.0 kg
20.0 kg
2.0 kg lighter
European efficiency
97.9 %
98.1 %
0.2 pp more efficient
Start voltage
180 V
250 V
70 V earlier start
MPPT voltage range
160-1000 V
200-1000 V
160-1000 V vs 200-1000 V
Dimensions
480x370x195 mm
485x370x160 mm
480x370x195 mm vs 485x370x160 mm
02
Full specification
Parameter
SG12RT-P2
SG12KTL-M
Difference
AC output
Rated AC power
12.00 kW
12.00 kW
Same
Max AC power
12.00 kW
12.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
20.0 A
20.0 A
Same
PV input
Max PV power
18.00 kW
-
Not published by Sungrow
DC/AC ratio
1.50
-
Not published by Sungrow
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
160-1000 V
200-1000 V
160-1000 V vs 200-1000 V
Start voltage
180 V
250 V
-70 V for SG12RT-P2
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
32.0 A
11.0 A
+21.0 A for SG12RT-P2
Efficiency
European efficiency
97.9 %
98.1 %
+0.2 pp for SG12KTL-M
Max efficiency
98.5 %
98.6 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
18.0 kg
20.0 kg
-2.0 kg for SG12RT-P2
Weight per kW
1.5 kg/kW
1.7 kg/kW
Effectively the same
Dimensions
480x370x195 mm
485x370x160 mm
480x370x195 mm vs 485x370x160 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
Yes
-
Not published by Sungrow
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG12RT-P2 vs Growatt MOD 12KTL3-X
9 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Sungrow SG12RT-P2 vs Growatt MOD 12KTL3-X2(Pro)
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Sungrow SG12RT-P2 vs Sungrow SG12RT-20
4 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Sungrow SG12KTL-M vs GoodWe GW12KLN-DT
6 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.