Sungrow SG12RT-20 vs Growatt MOD 12KTL3-X
VS
The verdict
MOD 12KTL3-X leads on the differences that matter
The largest is weight: 3.0 kg lighter. 11 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
11
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 20 parameters
What actually differs
Parameter
SG12RT-20
MOD 12KTL3-X
Difference
Weight
17.0 kg
14.0 kg
3.0 kg lighter
Max input current per tracker
25.0 A
26.0 A
1.0 A more headroom
Ingress protection
IP65
IP66
IP65 vs IP66
Weight per kW
1.4 kg/kW
1.2 kg/kW
0.2 kg/kW lighter
MPPT voltage range
160-1000 V
140-1000 V
160-1000 V vs 140-1000 V
Start voltage
180 V
160 V
20 V earlier start
Strings per tracker
1
2
1 string apart
Dimensions
480x370x195 mm
387x425x178 mm
480x370x195 mm vs 387x425x178 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SG12RT-20
MOD 12KTL3-X
Difference
AC output
Rated AC power
12.00 kW
12.00 kW
Same
Max AC power
12.00 kW
12.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
20.0 A
20.0 A
Same
PV input
Max PV power
-
18.00 kW
Not published by Sungrow
DC/AC ratio
-
1.50
Not published by Sungrow
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
160-1000 V
140-1000 V
160-1000 V vs 140-1000 V
Start voltage
180 V
160 V
-20 V for MOD 12KTL3-X
MPP trackers
2
2
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
25.0 A
26.0 A
+1.0 A for MOD 12KTL3-X
Efficiency
European efficiency
98.1 %
98.2 %
Effectively the same
Max efficiency
98.5 %
98.6 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
17.0 kg
14.0 kg
-3.0 kg for MOD 12KTL3-X
Weight per kW
1.4 kg/kW
1.2 kg/kW
-0.2 kg/kW for MOD 12KTL3-X
Dimensions
480x370x195 mm
387x425x178 mm
480x370x195 mm vs 387x425x178 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG12RT-20 vs Growatt MOD 12KTL3-X2(Pro)
7 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Sungrow SG12RT-20 vs Sungrow SG12KTL-M
7 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Sungrow SG12RT-20 vs GoodWe GW12KLN-DT
6 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.