Sungrow SG10KTL-M vs GoodWe GW10K-MS-CN-G40
VS
The verdict
GW10K-MS-CN-G40 leads on the differences that matter
The largest is max dc voltage: 500 V apart. 6 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
6
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 19 parameters
What actually differs
Parameter
SG10KTL-M
GW10K-MS-CN-G40
Difference
Max DC voltage
1100 V
600 V
500 V apart
Max input current per tracker
11.0 A
20.0 A
9.0 A more headroom
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Weight
20.0 kg
16.0 kg
4.0 kg lighter
Max efficiency
98.6 %
98.1 %
0.5 pp more efficient
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
16.5 A
50.0 A
33.5 A apart
Start voltage
250 V
50 V
200 V earlier start
Weight per kW
2.0 kg/kW
1.6 kg/kW
0.4 kg/kW lighter
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
200-1000 V
40-560 V
200-1000 V vs 40-560 V
Dimensions
485x370x160 mm
365x493x187 mm
485x370x160 mm vs 365x493x187 mm
02
Full specification
Parameter
SG10KTL-M
GW10K-MS-CN-G40
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
16.5 A
50.0 A
33.5 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
600 V
500 V apart
MPPT voltage range
200-1000 V
40-560 V
200-1000 V vs 40-560 V
Start voltage
250 V
50 V
-200 V for GW10K-MS-CN-G40
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
11.0 A
20.0 A
+9.0 A for GW10K-MS-CN-G40
Efficiency
European efficiency
98.1 %
-
Not published by GoodWe
Max efficiency
98.6 %
98.1 %
+0.5 pp for SG10KTL-M
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
20.0 kg
16.0 kg
-4.0 kg for GW10K-MS-CN-G40
Weight per kW
2.0 kg/kW
1.6 kg/kW
-0.4 kg/kW for GW10K-MS-CN-G40
Dimensions
485x370x160 mm
365x493x187 mm
485x370x160 mm vs 365x493x187 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
30 dB
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sungrow
Ethernet
-
Yes
Not published by Sungrow
Arc fault protection
-
Yes
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sungrow SG10KTL-M vs Growatt MOD 10KTL3-X2(Pro)
8 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Sungrow SG10KTL-M vs Growatt MOD 10KTL3-X
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Sungrow SG10KTL-M vs Sungrow SG10RT-20
7 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.