SolarEdge SE66.6K (K66.6SE) - Secondary unit vs SolarEdge SE66.6K (Synergy, 277/480V)

SolarEdge
SolarEdge SE66.6K (K66.6SE) - Secondary unit
66.6 kW
98.0 % euro
Grid-tie
VS

SolarEdge
SolarEdge SE66.6K (Synergy, 277/480V)
66.6 kW
98.0 % euro
Grid-tie
The verdict
One difference, none of them an advantage
The largest is dimensions: 540x315x260 mm vs 940x315x260 mm. 17 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See the one differenceHow alike are they
17
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
1 of 18 parameters
What actually differs
Parameter
(K66.6SE) - Secondary unit
(Synergy, 277/480V)
Difference
Dimensions
540x315x260 mm
940x315x260 mm
540x315x260 mm vs 940x315x260 mm
02
Full specification
Parameter
(K66.6SE) - Secondary unit
(Synergy, 277/480V)
Difference
AC output
Rated AC power
66.60 kW
66.60 kW
Same
Max AC power
66.60 kW
66.60 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
480 V
480 V
Same
Max AC current
80.0 A
80.0 A
Same
PV input
Max PV power
90.00 kW
90.00 kW
Same
DC/AC ratio
1.35
1.35
Same
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
-
680-1000 V
Not published by SolarEdge
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
40.0 A
Not published by SolarEdge
Efficiency
European efficiency
98.0 %
98.0 %
Same
Max efficiency
98.1 %
98.1 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
45.0 kg
-
Not published by SolarEdge
Weight per kW
0.7 kg/kW
-
Not published by SolarEdge
Dimensions
540x315x260 mm
940x315x260 mm
540x315x260 mm vs 940x315x260 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
60 dB
60 dB
Same
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SolarEdge SE66.6K (K66.6SE) - Secondary unit vs SolarEdge SE66.6K (K66.6SE)
The same specification on paper
Same type, similar size
SolarEdge
SolarEdge SE66.6K (K66.6SE) - Secondary unit vs SolarEdge SE66.6K (K66.6SE) - Primary unit
2 differences, the largest is weight
Same type, similar size
SolarEdge
SolarEdge SE66.6K (K66.6SE) - Secondary unit vs SolarEdge SE66.6K (Synergy) - secondary unit (physical)
The same specification on paper
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.