SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid
vs
SUN2000-33KTL-NH
5 of 15 identical
Swap
Change inverters
SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid vs Huawei SUN2000-33KTL-NH
SolarEdge
SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid
33.3 kW
98.0 % euro
Grid-tie
VS
The verdict
SUN2000-33KTL-NH leads on the differences that matter
The largest is max dc voltage: 100 V apart. 5 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
5
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 15 parameters
What actually differs
Parameter
SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid
SUN2000-33KTL-NH
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
40.0 A
26.0 A
14.0 A more headroom
Max efficiency
98.1 %
98.8 %
0.7 pp more efficient
Max AC power
33.30 kW
38.00 kW
4.70 kW apart
Weight
45.0 kg
43.0 kg
2.0 kg lighter
Max AC current
40.0 A
45.8 A
5.8 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
680-1000 V
200-1000 V
680-1000 V vs 200-1000 V
Dimensions
540x315x260 mm
530x681x270 mm
540x315x260 mm vs 530x681x270 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid
SUN2000-33KTL-NH
Difference
AC output
Rated AC power
33.30 kW
33.30 kW
Same
Max AC power
33.30 kW
38.00 kW
4.70 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
480 V
-
Not published by Huawei
Max AC current
40.0 A
45.8 A
5.8 A apart
PV input
Max PV power
50.00 kW
-
Not published by Huawei
DC/AC ratio
1.50
-
Not published by Huawei
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
680-1000 V
200-1000 V
680-1000 V vs 200-1000 V
Start voltage
-
200 V
Not published by SolarEdge
MPP trackers
-
4
Not published by SolarEdge
Strings per tracker
-
2
Not published by SolarEdge
Max input current per tracker
40.0 A
26.0 A
+14.0 A for SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid
Efficiency
European efficiency
98.0 %
-
Not published by Huawei
Max efficiency
98.1 %
98.8 %
+0.7 pp for SUN2000-33KTL-NH
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
45.0 kg
43.0 kg
-2.0 kg for SUN2000-33KTL-NH
Weight per kW
1.4 kg/kW
1.3 kg/kW
Effectively the same
Dimensions
540x315x260 mm
530x681x270 mm
540x315x260 mm vs 530x681x270 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
55 dB
-
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Huawei
Ethernet
Yes
-
Not published by Huawei
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
-
Not published by Huawei
Warranty
Warranty
20 yrs
-
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid vs SolarEdge SE33.3K
7 differences, the largest is max pv power
Same type, similar size
SolarEdge
SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid vs SolarEdge SE33.3K (K33.3SE) with DC Safety Unit (optional)
2 differences, the largest is weight
Same type, similar size
Fronius International
SolarEdge SE33.3K (K33.3SE) - Three Phase Inverter for 277/480V Grid vs Fronius Verto 33.3
8 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.