SolarEdge SE27.6K (Three Phase)
vs
SE50K (for 220V/230V line-to-line grids)
9 of 17 identical
Swap
Change inverters
SolarEdge SE27.6K (Three Phase) vs SolarEdge SE50K (for 220V/230V line-to-line grids)

SolarEdge
SolarEdge SE27.6K (Three Phase)
27.6 kW
98.0 % euro
Grid-tie
VS

SolarEdge
SE50K (for 220V/230V line-to-line grids)
29 kW
98.0 % euro
Grid-tie
The verdict
8 differences, and they point both ways
The largest is rated ac power: 1.40 kW apart. 9 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
9
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 17 parameters
What actually differs
Parameter
SolarEdge SE27.6K (Three Phase)
SE50K (for 220V/230V line-to-line grids)
Difference
Rated AC power
27.60 kW
29.00 kW
1.40 kW apart
Max DC voltage
1000 V
600 V
400 V apart
Max AC power
27.60 kW
29.00 kW
1.40 kW apart
Max PV power
37.25 kW
50.75 kW
13.50 kW apart
DC/AC ratio
1.35
1.75
0.40 more oversizing headroom
Noise
55 dB
67 dB
12 dB quieter
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
40.0 A
72.5 A
32.5 A apart
02
Full specification
Parameter
SolarEdge SE27.6K (Three Phase)
SE50K (for 220V/230V line-to-line grids)
Difference
AC output
Rated AC power
27.60 kW
29.00 kW
1.40 kW apart
Max AC power
27.60 kW
29.00 kW
1.40 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
40.0 A
72.5 A
32.5 A apart
PV input
Max PV power
37.25 kW
50.75 kW
13.50 kW apart
DC/AC ratio
1.35
1.75
+0.40 for SE50K (for 220V/230V line-to-line grids)
Max DC voltage
1000 V
600 V
400 V apart
MPPT voltage range
-
370-600 V
Not published by SolarEdge
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
98.0 %
98.0 %
Same
Max efficiency
98.3 %
98.3 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
45.0 kg
-
Not published by SolarEdge
Weight per kW
1.6 kg/kW
-
Not published by SolarEdge
Dimensions
540x315x260 mm
-
Not published by SolarEdge
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
55 dB
67 dB
-12 dB for SolarEdge SE27.6K (Three Phase)
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
-
Yes
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SolarEdge SE27.6K (Three Phase) vs SolarEdge SE27.6K
5 differences, the largest is max pv power
Same type, similar size
Fronius International
SolarEdge SE27.6K (Three Phase) vs Fronius Eco 27.0-3-S
8 differences, the largest is rated ac power
Same type, similar size
Fronius International
SolarEdge SE27.6K (Three Phase) vs Fronius Verto 27.0
10 differences, the largest is rated ac power
Same type, similar size
Huawei
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Huawei SUN2000-29.9KTL-M3
11 differences, the largest is rated ac power
Same type, similar size
SolarEdge
SolarEdge SE50K (for 220V/230V line-to-line grids) vs SolarEdge SE30K
8 differences, the largest is rated ac power
Same type, similar size
Fronius International
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Fronius Verto 30.0
12 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.