SolarEdge SE90K (Synergy, 380/400V) vs Deye SUN-90K-G03
VS
The verdict
13 differences, and they point both ways
The largest is warranty: 15 yrs longer. 9 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
9
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 22 parameters
What actually differs
Parameter
SE90K (Synergy, 380/400V)
SUN-90K-G03
Difference
Warranty
20 yrs
5 yrs
15 yrs longer
Max AC power
90.00 kW
99.00 kW
9.00 kW apart
Max PV power
157.50 kW
135.00 kW
22.50 kW apart
DC/AC ratio
1.75
1.50
0.25 more oversizing headroom
Weight
32.0 kg
81.0 kg
49.0 kg lighter
Noise
67 dB
55 dB
12 dB quieter
Max efficiency
98.3 %
98.8 %
0.5 pp more efficient
European efficiency
98.0 %
98.3 %
0.3 pp more efficient
Weight per kW
0.4 kg/kW
0.9 kg/kW
0.5 kg/kW lighter
Max AC current
145.0 A
150.0 A
5.0 A apart
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
MPPT voltage range
680-1000 V
200-850 V
680-1000 V vs 200-850 V
Dimensions
558x328x273 mm
568x838x324 mm
558x328x273 mm vs 568x838x324 mm
02
Full specification
Parameter
SE90K (Synergy, 380/400V)
SUN-90K-G03
Difference
AC output
Rated AC power
90.00 kW
90.00 kW
Same
Max AC power
90.00 kW
99.00 kW
9.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
145.0 A
150.0 A
5.0 A apart
PV input
Max PV power
157.50 kW
135.00 kW
22.50 kW apart
DC/AC ratio
1.75
1.50
+0.25 for SE90K (Synergy, 380/400V)
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
680-1000 V
200-850 V
680-1000 V vs 200-850 V
Start voltage
-
250 V
Not published by SolarEdge
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
40.0 A
Not published by SolarEdge
Efficiency
European efficiency
98.0 %
98.3 %
+0.3 pp for SUN-90K-G03
Max efficiency
98.3 %
98.8 %
+0.5 pp for SUN-90K-G03
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
32.0 kg
81.0 kg
-49.0 kg for SE90K (Synergy, 380/400V)
Weight per kW
0.4 kg/kW
0.9 kg/kW
-0.5 kg/kW for SE90K (Synergy, 380/400V)
Dimensions
558x328x273 mm
568x838x324 mm
558x328x273 mm vs 568x838x324 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
67 dB
55 dB
-12 dB for SUN-90K-G03
Max operating temperature
60 °C
65 °C
+5 °C for SUN-90K-G03
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
20 yrs
5 yrs
+15 yrs for SE90K (Synergy, 380/400V)
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SolarEdge SE90K (Synergy, 380/400V) vs SolarEdge SE90K (400V grid)
One difference: max ac current
Same type, similar size
SolarEdge
SolarEdge SE90K (Synergy, 380/400V) vs SolarEdge SE90K (IL00IBNQ4)
The same specification on paper
Same type, similar size
Huawei
SolarEdge SE90K (Synergy, 380/400V) vs Huawei SUN2000-62.5KTL-NHM0 (83.3kW / 270V configuration)
7 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.