Skip to main content
SE80KUS vs MAX 80KTL3 LV 6 of 17 identical Swap Change inverters

SolarEdge SE80KUS vs Growatt MAX 80KTL3 LV

SolarEdge
SE80KUS
80 kW Grid-tie
VS
Growatt MAX 80KTL3 LV
Growatt
MAX 80KTL3 LV
80 kW 98.5 % euro Grid-tie
The verdict

SE80KUS leads on the differences that matter

The largest is max dc voltage: 100 V apart. 6 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
6 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 17 parameters
Parameter SE80KUS MAX 80KTL3 LV Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max AC power 80.00 kW 88.80 kW 8.80 kW apart
Max PV power 140.00 kW 120.00 kW 20.00 kW apart
DC/AC ratio 1.75 1.50 0.25 more oversizing headroom
Weight 32.0 kg 86.0 kg 54.0 kg lighter
Weight per kW 0.4 kg/kW 1.1 kg/kW 0.7 kg/kW lighter
Nominal AC voltage 277 V 400 V 123 V apart
Max AC current 96.5 A 128.8 A 32.3 A apart
Ingress protection NEMA 3R IP65 NEMA 3R vs IP65
MPPT voltage range 370-1000 V 200-1000 V 370-1000 V vs 200-1000 V
Dimensions 558x328x273 mm 600x860x300 mm 558x328x273 mm vs 600x860x300 mm
02

Full specification

Parameter SE80KUS MAX 80KTL3 LV Difference
AC output
Rated AC power 80.00 kW 80.00 kW Same
Max AC power 80.00 kW 88.80 kW 8.80 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 277 V 400 V 123 V apart
Max AC current 96.5 A 128.8 A 32.3 A apart
PV input
Max PV power 140.00 kW 120.00 kW 20.00 kW apart
DC/AC ratio 1.75 1.50 +0.25 for SE80KUS
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 370-1000 V 200-1000 V 370-1000 V vs 200-1000 V
Start voltage - 250 V Not published by SolarEdge
MPP trackers - - Neither datasheet publishes this
Strings per tracker - 2 Not published by SolarEdge
Max input current per tracker - 26.0 A Not published by SolarEdge
Efficiency
European efficiency - 98.5 % Not published by SolarEdge
Max efficiency - 99.0 % Not published by SolarEdge
CEC efficiency 98.5 % - Not published by Growatt
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 32.0 kg 86.0 kg -54.0 kg for SE80KUS
Weight per kW 0.4 kg/kW 1.1 kg/kW -0.7 kg/kW for SE80KUS
Dimensions 558x328x273 mm 600x860x300 mm 558x328x273 mm vs 600x860x300 mm
Ingress protection NEMA 3R IP65 NEMA 3R vs IP65
Cooling forced-air forced-air Same
Noise 67 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by SolarEdge
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
SolarEdge SE80KUS vs GoodWe GW80KBF-MT
9 differences, the largest is max dc voltage
Same type, similar size
GoodWe
SolarEdge SE80KUS vs GoodWe GW80KHV-MT
9 differences, the largest is max dc voltage
Same type, similar size
GoodWe
SolarEdge SE80KUS vs GoodWe GW80K-MT
9 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MAX 80KTL3 LV vs Ginlong Solis S6-GC3P80K07-LV-ND
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.