SolarEdge SE66.6K (for 220V/230V line-to-line grids) vs Growatt MID 40KTL3-X

SolarEdge
SE66.6K (for 220V/230V line-to-line grids)
38.45 kW
98.0 % euro
Grid-tie
VS
The verdict
MID 40KTL3-X leads on the differences that matter
The largest is rated ac power: 1.55 kW apart. 7 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
7
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 18 parameters
What actually differs
Parameter
SE66.6K (for 220V/230V line-to-line grids)
MID 40KTL3-X
Difference
Rated AC power
38.45 kW
40.00 kW
1.55 kW apart
European efficiency
98.0 %
98.5 %
0.5 pp more efficient
Max DC voltage
600 V
1100 V
500 V apart
Max AC power
38.45 kW
44.00 kW
5.55 kW apart
Max PV power
67.28 kW
60.00 kW
7.28 kW apart
DC/AC ratio
1.75
1.50
0.25 more oversizing headroom
Max efficiency
98.3 %
98.8 %
0.5 pp more efficient
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
96.5 A
66.6 A
29.9 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
370-600 V
200-1000 V
370-600 V vs 200-1000 V
02
Full specification
Parameter
SE66.6K (for 220V/230V line-to-line grids)
MID 40KTL3-X
Difference
AC output
Rated AC power
38.45 kW
40.00 kW
1.55 kW apart
Max AC power
38.45 kW
44.00 kW
5.55 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
96.5 A
66.6 A
29.9 A apart
PV input
Max PV power
67.28 kW
60.00 kW
7.28 kW apart
DC/AC ratio
1.75
1.50
+0.25 for SE66.6K (for 220V/230V line-to-line grids)
Max DC voltage
600 V
1100 V
500 V apart
MPPT voltage range
370-600 V
200-1000 V
370-600 V vs 200-1000 V
Start voltage
-
250 V
Not published by SolarEdge
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
2
Not published by SolarEdge
Max input current per tracker
-
26.0 A
Not published by SolarEdge
Efficiency
European efficiency
98.0 %
98.5 %
+0.5 pp for MID 40KTL3-X
Max efficiency
98.3 %
98.8 %
+0.5 pp for MID 40KTL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
30.5 kg
Not published by SolarEdge
Weight per kW
-
0.8 kg/kW
Not published by SolarEdge
Dimensions
-
435x580x230 mm
Not published by SolarEdge
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
67 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
SolarEdge SE66.6K (for 220V/230V line-to-line grids) vs Huawei SUN2000-40KTL-M3
10 differences, the largest is rated ac power
Same type, similar size
Ginlong Solis
SolarEdge SE66.6K (for 220V/230V line-to-line grids) vs Solis-40K
10 differences, the largest is rated ac power
Same type, similar size
Sungrow
SolarEdge SE66.6K (for 220V/230V line-to-line grids) vs Sungrow SG40CX-P2
11 differences, the largest is rated ac power
Same type, similar size
Sungrow
Growatt MID 40KTL3-X vs Sungrow SG40CX
5 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.