SolarEdge SE50K (IL00IBNQ4) vs Solis-50K-HV
VS
The verdict
Solis-50K-HV leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 7 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
7
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 15 parameters
What actually differs
Parameter
SE50K (IL00IBNQ4)
Solis-50K-HV
Difference
European efficiency
98.0 %
98.5 %
0.5 pp more efficient
Max DC voltage
1000 V
1100 V
100 V apart
Max efficiency
98.3 %
99.0 %
0.7 pp more efficient
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Max PV power
87.50 kW
60.00 kW
27.50 kW apart
DC/AC ratio
1.75
1.20
0.55 more oversizing headroom
Max AC current
72.5 A
66.2 A
6.3 A apart
MPPT voltage range
680-1000 V
200-1000 V
680-1000 V vs 200-1000 V
02
Full specification
Parameter
SE50K (IL00IBNQ4)
Solis-50K-HV
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
72.5 A
66.2 A
6.3 A apart
PV input
Max PV power
87.50 kW
60.00 kW
27.50 kW apart
DC/AC ratio
1.75
1.20
+0.55 for SE50K (IL00IBNQ4)
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
680-1000 V
200-1000 V
680-1000 V vs 200-1000 V
Start voltage
-
200 V
Not published by SolarEdge
MPP trackers
-
4
Not published by SolarEdge
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
98.0 %
98.5 %
+0.5 pp for Solis-50K-HV
Max efficiency
98.3 %
99.0 %
+0.7 pp for Solis-50K-HV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
61.0 kg
Not published by SolarEdge
Weight per kW
-
1.2 kg/kW
Not published by SolarEdge
Dimensions
-
700x630x357 mm
Not published by SolarEdge
Ingress protection
IP65
IP65
Same
Cooling
forced-air
-
Not published by Ginlong Solis
Noise
67 dB
-
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
Yes
-
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
SolarEdge SE50K (IL00IBNQ4) vs Huawei SUN2000-50KTL-JPM0
7 differences, the largest is european efficiency
Same type, similar size
Huawei
SolarEdge SE50K (IL00IBNQ4) vs Huawei SUN2000-50KTL-M0
7 differences, the largest is european efficiency
Same type, similar size
Growatt
SolarEdge SE50K (IL00IBNQ4) vs Growatt MAX 50KTL3 LV
8 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Solis-50K-HV vs Sungrow SG50CX
6 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

