SE50K (for 220V/230V line-to-line grids)
vs
MID 30KTL3-X2 (Pro.E)
5 of 16 identical
Swap
Change inverters
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Growatt MID 30KTL3-X2 (Pro.E)

SolarEdge
SE50K (for 220V/230V line-to-line grids)
29 kW
98.0 % euro
Grid-tie
VS
The verdict
MID 30KTL3-X2 (Pro.E) leads on the differences that matter
The largest is rated ac power: 1.00 kW apart. 5 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
5
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 16 parameters
What actually differs
Parameter
SE50K (for 220V/230V line-to-line grids)
MID 30KTL3-X2 (Pro.E)
Difference
Rated AC power
29.00 kW
30.00 kW
1.00 kW apart
European efficiency
98.0 %
98.6 %
0.6 pp more efficient
Max DC voltage
600 V
1100 V
500 V apart
Max AC power
29.00 kW
30.00 kW
1.00 kW apart
Max PV power
50.75 kW
45.00 kW
5.75 kW apart
DC/AC ratio
1.75
1.50
0.25 more oversizing headroom
Max efficiency
98.3 %
98.8 %
0.5 pp more efficient
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
72.5 A
50.5 A
22.0 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
370-600 V
200-1000 V
370-600 V vs 200-1000 V
02
Full specification
Parameter
SE50K (for 220V/230V line-to-line grids)
MID 30KTL3-X2 (Pro.E)
Difference
AC output
Rated AC power
29.00 kW
30.00 kW
1.00 kW apart
Max AC power
29.00 kW
30.00 kW
1.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
72.5 A
50.5 A
22.0 A apart
PV input
Max PV power
50.75 kW
45.00 kW
5.75 kW apart
DC/AC ratio
1.75
1.50
+0.25 for SE50K (for 220V/230V line-to-line grids)
Max DC voltage
600 V
1100 V
500 V apart
MPPT voltage range
370-600 V
200-1000 V
370-600 V vs 200-1000 V
Start voltage
-
200 V
Not published by SolarEdge
MPP trackers
-
3
Not published by SolarEdge
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
40.0 A
Not published by SolarEdge
Efficiency
European efficiency
98.0 %
98.6 %
+0.6 pp for MID 30KTL3-X2 (Pro.E)
Max efficiency
98.3 %
98.8 %
+0.5 pp for MID 30KTL3-X2 (Pro.E)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
24.0 kg
Not published by SolarEdge
Weight per kW
-
0.8 kg/kW
Not published by SolarEdge
Dimensions
-
415x528x225 mm
Not published by SolarEdge
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
67 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Huawei SUN2000-29.9KTL-M3
11 differences, the largest is rated ac power
Same type, similar size
SolarEdge
SolarEdge SE50K (for 220V/230V line-to-line grids) vs SolarEdge SE30K
8 differences, the largest is rated ac power
Same type, similar size
Fronius International
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Fronius Verto 30.0
12 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MID 30KTL3-X2 (Pro.E) vs Growatt MID 30KTL3-X
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MID 30KTL3-X2 (Pro.E) vs Growatt MID 30KTL3-X2-1
5 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MID 30KTL3-X2 (Pro.E) vs GoodWe GW30K-MT
9 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.