SolarEdge SE5000H vs GoodWe GW5000N-EH
VS
The verdict
SE5000H leads on the differences that matter
The largest is european efficiency: 2.0 pp more efficient. 10 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
10
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 19 parameters
What actually differs
Parameter
SE5000H
GW5000N-EH
Difference
European efficiency
99.0 %
97.0 %
2.0 pp more efficient
Max DC voltage
480 V
580 V
100 V apart
Max efficiency
99.2 %
97.6 %
1.6 pp more efficient
Max PV power
10.00 kW
7.50 kW
2.50 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
Weight
12.0 kg
17.0 kg
5.0 kg lighter
Weight per kW
2.4 kg/kW
3.4 kg/kW
1.0 kg/kW lighter
Max AC current
23.0 A
21.7 A
1.3 A apart
Dimensions
459x370x154 mm
433x354x147 mm
459x370x154 mm vs 433x354x147 mm
02
Full specification
Parameter
SE5000H
GW5000N-EH
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.00 kW
5.00 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
23.0 A
21.7 A
1.3 A apart
PV input
Max PV power
10.00 kW
7.50 kW
2.50 kW apart
DC/AC ratio
2.00
1.50
+0.50 for SE5000H
Max DC voltage
480 V
580 V
100 V apart
MPPT voltage range
-
100-550 V
Not published by SolarEdge
Start voltage
-
85 V
Not published by SolarEdge
MPP trackers
-
2
Not published by SolarEdge
Strings per tracker
-
1
Not published by SolarEdge
Max input current per tracker
-
16.0 A
Not published by SolarEdge
Efficiency
European efficiency
99.0 %
97.0 %
+2.0 pp for SE5000H
Max efficiency
99.2 %
97.6 %
+1.6 pp for SE5000H
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
-
85 ~ 460
Not published by SolarEdge
Max charge current
-
25 A
Not published by SolarEdge
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
12.0 kg
17.0 kg
-5.0 kg for SE5000H
Weight per kW
2.4 kg/kW
3.4 kg/kW
-1.0 kg/kW for SE5000H
Dimensions
459x370x154 mm
433x354x147 mm
459x370x154 mm vs 433x354x147 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by GoodWe
Integrated DC switch
-
Yes
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SolarEdge SE5000H vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
3 differences, the largest is weight
Same type, similar size
Huawei
SolarEdge SE5000H vs Huawei SUN2000L-5KTL
8 differences, the largest is european efficiency
Same type, similar size
Growatt
SolarEdge SE5000H vs Growatt MOD 5000TL3-HU
11 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.