SolarEdge SE27.6K vs SolarEdge SE50K (for 220V/230V line-to-line grids)
VS

SolarEdge
SE50K (for 220V/230V line-to-line grids)
29 kW
98.0 % euro
Grid-tie
The verdict
7 differences, none of them an advantage
The largest is rated ac power: 1.40 kW apart. 9 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
9
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 16 parameters
What actually differs
Parameter
SE27.6K
SE50K (for 220V/230V line-to-line grids)
Difference
Rated AC power
27.60 kW
29.00 kW
1.40 kW apart
Max DC voltage
1000 V
600 V
400 V apart
Max AC power
27.60 kW
29.00 kW
1.40 kW apart
Max PV power
48.30 kW
50.75 kW
2.45 kW apart
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
40.0 A
72.5 A
32.5 A apart
MPPT voltage range
680-1000 V
370-600 V
680-1000 V vs 370-600 V
02
Full specification
Parameter
SE27.6K
SE50K (for 220V/230V line-to-line grids)
Difference
AC output
Rated AC power
27.60 kW
29.00 kW
1.40 kW apart
Max AC power
27.60 kW
29.00 kW
1.40 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
40.0 A
72.5 A
32.5 A apart
PV input
Max PV power
48.30 kW
50.75 kW
2.45 kW apart
DC/AC ratio
1.75
1.75
Same
Max DC voltage
1000 V
600 V
400 V apart
MPPT voltage range
680-1000 V
370-600 V
680-1000 V vs 370-600 V
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
98.0 %
98.0 %
Same
Max efficiency
-
98.3 %
Not published by SolarEdge
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
32.0 kg
-
Not published by SolarEdge
Weight per kW
1.2 kg/kW
-
Not published by SolarEdge
Dimensions
558x328x273 mm
-
Not published by SolarEdge
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
67 dB
Not published by SolarEdge
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
-
Yes
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SolarEdge SE27.6K vs SolarEdge SE27.6K (Three Phase)
5 differences, the largest is max pv power
Same type, similar size
Fronius International
SolarEdge SE27.6K vs Fronius Eco 27.0-3-S
8 differences, the largest is rated ac power
Same type, similar size
Fronius International
SolarEdge SE27.6K vs Fronius Verto 27.0
11 differences, the largest is rated ac power
Same type, similar size
Huawei
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Huawei SUN2000-29.9KTL-M3
11 differences, the largest is rated ac power
Same type, similar size
SolarEdge
SolarEdge SE50K (for 220V/230V line-to-line grids) vs SolarEdge SE30K
8 differences, the largest is rated ac power
Same type, similar size
Fronius International
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Fronius Verto 30.0
12 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.