Skip to main content
SE27.6K vs SE50K (for 220V/230V line-to-line grids) 9 of 16 identical Swap Change inverters

SolarEdge SE27.6K vs SolarEdge SE50K (for 220V/230V line-to-line grids)

SolarEdge SE27.6K
SolarEdge
SE27.6K
27.6 kW 98.0 % euro Grid-tie
VS
SolarEdge SE50K (for 220V/230V line-to-line grids)
SolarEdge
SE50K (for 220V/230V line-to-line grids)
29 kW 98.0 % euro Grid-tie
The verdict

7 differences, none of them an advantage

The largest is rated ac power: 1.40 kW apart. 9 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
9 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 16 parameters
Parameter SE27.6K SE50K (for 220V/230V line-to-line grids) Difference
Rated AC power 27.60 kW 29.00 kW 1.40 kW apart
Max DC voltage 1000 V 600 V 400 V apart
Max AC power 27.60 kW 29.00 kW 1.40 kW apart
Max PV power 48.30 kW 50.75 kW 2.45 kW apart
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 40.0 A 72.5 A 32.5 A apart
MPPT voltage range 680-1000 V 370-600 V 680-1000 V vs 370-600 V
02

Full specification

Parameter SE27.6K SE50K (for 220V/230V line-to-line grids) Difference
AC output
Rated AC power 27.60 kW 29.00 kW 1.40 kW apart
Max AC power 27.60 kW 29.00 kW 1.40 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 40.0 A 72.5 A 32.5 A apart
PV input
Max PV power 48.30 kW 50.75 kW 2.45 kW apart
DC/AC ratio 1.75 1.75 Same
Max DC voltage 1000 V 600 V 400 V apart
MPPT voltage range 680-1000 V 370-600 V 680-1000 V vs 370-600 V
Start voltage - - Neither datasheet publishes this
MPP trackers - - Neither datasheet publishes this
Strings per tracker - - Neither datasheet publishes this
Max input current per tracker - - Neither datasheet publishes this
Efficiency
European efficiency 98.0 % 98.0 % Same
Max efficiency - 98.3 % Not published by SolarEdge
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 32.0 kg - Not published by SolarEdge
Weight per kW 1.2 kg/kW - Not published by SolarEdge
Dimensions 558x328x273 mm - Not published by SolarEdge
Ingress protection IP65 IP65 Same
Cooling forced-air forced-air Same
Noise - 67 dB Not published by SolarEdge
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch - Yes Not published by SolarEdge
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
SolarEdge SE27.6K vs SolarEdge SE27.6K (Three Phase)
5 differences, the largest is max pv power
Same type, similar size
Fronius International
SolarEdge SE27.6K vs Fronius Eco 27.0-3-S
8 differences, the largest is rated ac power
Same type, similar size
Fronius International
SolarEdge SE27.6K vs Fronius Verto 27.0
11 differences, the largest is rated ac power
Same type, similar size
Huawei
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Huawei SUN2000-29.9KTL-M3
11 differences, the largest is rated ac power
Same type, similar size
SolarEdge
SolarEdge SE50K (for 220V/230V line-to-line grids) vs SolarEdge SE30K
8 differences, the largest is rated ac power
Same type, similar size
Fronius International
SolarEdge SE50K (for 220V/230V line-to-line grids) vs Fronius Verto 30.0
12 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.