Skip to main content
SE17K (Delta grid version; part no. SExxK-xxxxxbxx4) vs MOD 10KTL3-X2(Pro) 7 of 20 identical Swap Change inverters

SolarEdge SE17K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Growatt MOD 10KTL3-X2(Pro)

SolarEdge SE17K (Delta grid version; part no. SExxK-xxxxxbxx4)
SolarEdge
SE17K (Delta grid version; part no. SExxK-xxxxxbxx4)
10 kW 97.7 % euro Grid-tie
VS
Growatt MOD 10KTL3-X2(Pro)
Growatt
MOD 10KTL3-X2(Pro)
10 kW 98.2 % euro Grid-tie
The verdict

MOD 10KTL3-X2(Pro) leads on the differences that matter

The largest is european efficiency: 0.5 pp more efficient. 7 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
7 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 20 parameters
Parameter SE17K (Delta grid version; part no. SExxK-xxxxxbxx4) MOD 10KTL3-X2(Pro) Difference
European efficiency 97.7 % 98.2 % 0.5 pp more efficient
Max DC voltage 600 V 1100 V 500 V apart
Max efficiency 98.0 % 98.6 % 0.6 pp more efficient
Max PV power 13.50 kW 15.00 kW 1.50 kW apart
Weight 30.7 kg 14.6 kg 16.1 kg lighter
Weight per kW 3.1 kg/kW 1.5 kg/kW 1.6 kg/kW lighter
DC/AC ratio 1.35 1.50 0.15 more oversizing headroom
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.0 A 16.0 A 10.0 A apart
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 370-600 V 140-1000 V 370-600 V vs 140-1000 V
Dimensions 540x315x260 mm 387x425x178 mm 540x315x260 mm vs 387x425x178 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter SE17K (Delta grid version; part no. SExxK-xxxxxbxx4) MOD 10KTL3-X2(Pro) Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 10.00 kW 10.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.0 A 16.0 A 10.0 A apart
PV input
Max PV power 13.50 kW 15.00 kW 1.50 kW apart
DC/AC ratio 1.35 1.50 +0.15 for MOD 10KTL3-X2(Pro)
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 370-600 V 140-1000 V 370-600 V vs 140-1000 V
Start voltage - 160 V Not published by SolarEdge
MPP trackers - 2 Not published by SolarEdge
Strings per tracker - 1 Not published by SolarEdge
Max input current per tracker - 20.0 A Not published by SolarEdge
Efficiency
European efficiency 97.7 % 98.2 % +0.5 pp for MOD 10KTL3-X2(Pro)
Max efficiency 98.0 % 98.6 % +0.6 pp for MOD 10KTL3-X2(Pro)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 30.7 kg 14.6 kg -16.1 kg for MOD 10KTL3-X2(Pro)
Weight per kW 3.1 kg/kW 1.5 kg/kW -1.6 kg/kW for MOD 10KTL3-X2(Pro)
Dimensions 540x315x260 mm 387x425x178 mm 540x315x260 mm vs 387x425x178 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air natural forced-air vs natural
Noise 50 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - 8 yrs Not published by SolarEdge
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
SolarEdge SE17K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Growatt MOD 10KTL3-X
13 differences, the largest is max dc voltage
Same type, similar size
Sungrow
SolarEdge SE17K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Sungrow SG10KTL-M
10 differences, the largest is max dc voltage
Same type, similar size
Sungrow
SolarEdge SE17K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Sungrow SG10RT-20
9 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Growatt MOD 10KTL3-X2(Pro) vs SOFAR 11KTLX-G3
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.