SE15K (Delta grid version; part no. SExxK-xxxxxbxx4)
vs
MOD 9000TL3-X
4 of 19 identical
Swap
Change inverters
SolarEdge SE15K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Growatt MOD 9000TL3-X

SolarEdge
SE15K (Delta grid version; part no. SExxK-xxxxxbxx4)
8.7 kW
97.6 % euro
Grid-tie
VS
The verdict
MOD 9000TL3-X leads on the differences that matter
The largest is rated ac power: 0.30 kW apart. 4 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 19 parameters
What actually differs
Parameter
SE15K (Delta grid version; part no. SExxK-xxxxxbxx4)
MOD 9000TL3-X
Difference
Rated AC power
8.70 kW
9.00 kW
0.30 kW apart
European efficiency
97.6 %
98.1 %
0.5 pp more efficient
Max DC voltage
600 V
1100 V
500 V apart
Max efficiency
98.0 %
98.6 %
0.6 pp more efficient
Max AC power
8.70 kW
9.00 kW
0.30 kW apart
Max PV power
11.74 kW
13.50 kW
1.76 kW apart
Weight
30.7 kg
14.0 kg
16.7 kg lighter
Weight per kW
3.5 kg/kW
1.6 kg/kW
2.0 kg/kW lighter
DC/AC ratio
1.35
1.50
0.15 more oversizing headroom
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
23.0 A
15.0 A
8.0 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
370-600 V
140-1000 V
370-600 V vs 140-1000 V
Dimensions
540x315x260 mm
387x425x178 mm
540x315x260 mm vs 387x425x178 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SE15K (Delta grid version; part no. SExxK-xxxxxbxx4)
MOD 9000TL3-X
Difference
AC output
Rated AC power
8.70 kW
9.00 kW
0.30 kW apart
Max AC power
8.70 kW
9.00 kW
0.30 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
23.0 A
15.0 A
8.0 A apart
PV input
Max PV power
11.74 kW
13.50 kW
1.76 kW apart
DC/AC ratio
1.35
1.50
+0.15 for MOD 9000TL3-X
Max DC voltage
600 V
1100 V
500 V apart
MPPT voltage range
370-600 V
140-1000 V
370-600 V vs 140-1000 V
Start voltage
-
160 V
Not published by SolarEdge
MPP trackers
-
2
Not published by SolarEdge
Strings per tracker
-
1
Not published by SolarEdge
Max input current per tracker
-
13.0 A
Not published by SolarEdge
Efficiency
European efficiency
97.6 %
98.1 %
+0.5 pp for MOD 9000TL3-X
Max efficiency
98.0 %
98.6 %
+0.6 pp for MOD 9000TL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
30.7 kg
14.0 kg
-16.7 kg for MOD 9000TL3-X
Weight per kW
3.5 kg/kW
1.6 kg/kW
-2.0 kg/kW for MOD 9000TL3-X
Dimensions
540x315x260 mm
387x425x178 mm
540x315x260 mm vs 387x425x178 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
50 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
-
Yes
Not published by SolarEdge
Warranty
Warranty
-
5 yrs
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
SolarEdge SE15K (Delta grid version; part no. SExxK-xxxxxbxx4) vs GoodWe GW8500-MS
11 differences, the largest is rated ac power
Same type, similar size
Ginlong Solis
SolarEdge SE15K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Ginlong Solis S6-GR3P-9K02-NV-ND
15 differences, the largest is rated ac power
Same type, similar size
Ginlong Solis
SolarEdge SE15K (Delta grid version; part no. SExxK-xxxxxbxx4) vs Solis-3P9K-4G
13 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MOD 9000TL3-X vs Growatt MIN 9000TL-X
12 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MOD 9000TL3-X vs SolarEdge SE9K-RWZZZBEN4 (per inverter; bundle is 2×SE9K, marketed as SE18K-BUNDLE*)
9 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.