SolarEdge SE10K (Three Phase, Delta Grids) vs Growatt MOD 6000TL3-HU

SolarEdge
SE10K (Three Phase, Delta Grids)
5.8 kW
97.6 % euro
Hybrid
VS
The verdict
MOD 6000TL3-HU leads on the differences that matter
The largest is rated ac power: 0.20 kW apart. 4 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 19 parameters
What actually differs
Parameter
SE10K (Three Phase, Delta Grids)
MOD 6000TL3-HU
Difference
Rated AC power
5.80 kW
6.00 kW
0.20 kW apart
Max DC voltage
600 V
1000 V
400 V apart
Max AC power
5.80 kW
6.60 kW
0.80 kW apart
Max PV power
7.83 kW
12.00 kW
4.17 kW apart
DC/AC ratio
1.35
2.00
0.65 more oversizing headroom
Weight
16.4 kg
19.0 kg
2.6 kg lighter
Noise
50 dB
29 dB
21 dB quieter
European efficiency
97.6 %
97.8 %
0.2 pp more efficient
Max efficiency
98.0 %
98.3 %
0.3 pp more efficient
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
16.0 A
10.0 A
6.0 A apart
Weight per kW
2.8 kg/kW
3.2 kg/kW
0.3 kg/kW lighter
Ingress protection
IP65
IP66
IP65 vs IP66
Dimensions
540x315x260 mm
468x408x202 mm
540x315x260 mm vs 468x408x202 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SE10K (Three Phase, Delta Grids)
MOD 6000TL3-HU
Difference
AC output
Rated AC power
5.80 kW
6.00 kW
0.20 kW apart
Max AC power
5.80 kW
6.60 kW
0.80 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
16.0 A
10.0 A
6.0 A apart
PV input
Max PV power
7.83 kW
12.00 kW
4.17 kW apart
DC/AC ratio
1.35
2.00
+0.65 for MOD 6000TL3-HU
Max DC voltage
600 V
1000 V
400 V apart
MPPT voltage range
-
140-1000 V
Not published by SolarEdge
Start voltage
-
180 V
Not published by SolarEdge
MPP trackers
-
2
Not published by SolarEdge
Strings per tracker
-
1
Not published by SolarEdge
Max input current per tracker
-
20.0 A
Not published by SolarEdge
Efficiency
European efficiency
97.6 %
97.8 %
+0.2 pp for MOD 6000TL3-HU
Max efficiency
98.0 %
98.3 %
+0.3 pp for MOD 6000TL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
-
600-980 V
Not published by SolarEdge
Max charge current
-
25 A
Not published by SolarEdge
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
16.4 kg
19.0 kg
-2.6 kg for SE10K (Three Phase, Delta Grids)
Weight per kW
2.8 kg/kW
3.2 kg/kW
-0.3 kg/kW for SE10K (Three Phase, Delta Grids)
Dimensions
540x315x260 mm
468x408x202 mm
540x315x260 mm vs 468x408x202 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
50 dB
29 dB
-21 dB for MOD 6000TL3-HU
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
-
Yes
Not published by SolarEdge
Integrated DC switch
-
Yes
Not published by SolarEdge
Warranty
Warranty
-
10 yrs
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SolarEdge SE10K (Three Phase, Delta Grids) vs SolarEdge SE6000H
13 differences, the largest is rated ac power
Same type, similar size
Huawei
SolarEdge SE10K (Three Phase, Delta Grids) vs Huawei SUN2000-6KTL-L1
12 differences, the largest is rated ac power
Same type, similar size
Huawei
SolarEdge SE10K (Three Phase, Delta Grids) vs Huawei SUN2000-6KTL-M1
11 differences, the largest is rated ac power
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-M1 (High current version)
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.