SolarEdge SE10000H vs SolarEdge SE10K-ILB48
VS
The verdict
SE10000H leads on the differences that matter
The largest is max efficiency: 1.2 pp more efficient. 7 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
7
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 15 parameters
What actually differs
Parameter
SE10000H
SE10K-ILB48
Difference
Max efficiency
99.2 %
98.0 %
1.2 pp more efficient
Weight
19.6 kg
37.0 kg
17.4 kg lighter
Weight per kW
2.0 kg/kW
3.7 kg/kW
1.7 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
45.5 A
16.0 A
29.5 A apart
Dimensions
535x370x185 mm
907x317x192 mm
535x370x185 mm vs 907x317x192 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SE10000H
SE10K-ILB48
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
10.00 kW
10.00 kW
Same
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
45.5 A
16.0 A
29.5 A apart
PV input
Max PV power
20.00 kW
20.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
480 V
-
Not published by SolarEdge
MPPT voltage range
-
750-900 V
Not published by SolarEdge
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
99.0 %
-
Not published by SolarEdge
Max efficiency
99.2 %
98.0 %
+1.2 pp for SE10000H
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
-
40 - 62 Vdc
Not published by SolarEdge
Max charge current
-
125 A
Not published by SolarEdge
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
19.6 kg
37.0 kg
-17.4 kg for SE10000H
Weight per kW
2.0 kg/kW
3.7 kg/kW
-1.7 kg/kW for SE10000H
Dimensions
535x370x185 mm
907x317x192 mm
535x370x185 mm vs 907x317x192 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
50 dB
Not published by SolarEdge
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by SolarEdge
Ethernet
Yes
-
Not published by SolarEdge
Arc fault protection
Yes
-
Not published by SolarEdge
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
12 yrs
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SolarEdge SE10000H vs Growatt MOD 10KTL3-XH
11 differences, the largest is european efficiency
Same type, similar size
Growatt
SolarEdge SE10000H vs Growatt MOD 10KTL3-HU
8 differences, the largest is european efficiency
Same type, similar size
Huawei
SolarEdge SE10000H vs Huawei SUN2000-10KTL-M1
12 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.