SOFAR 7KTLM-G3
Sofar Solar
SOFAR 7KTLM-G3
7 kW 97.3 % euro Grid-tie
VS
Sungrow SG5.0RT
Sungrow
SG5.0RT
7 kW 97.7 % euro Grid-tie
The verdict

SG5.0RT leads on the differences that matter

The largest is max dc voltage: 500 V apart. 6 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
6 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 21 parameters
Parameter SOFAR 7KTLM-G3 SG5.0RT Difference
Max DC voltage 600 V 1100 V 500 V apart
Max input current per tracker 20.0 A 25.0 A 5.0 A more headroom
European efficiency 97.3 % 97.7 % 0.4 pp more efficient
Max AC power 7.00 kW 7.70 kW 0.70 kW apart
Max efficiency 98.1 % 98.4 % 0.3 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 35.0 A 11.7 A 23.3 A apart
Start voltage 90 V 180 V 90 V earlier start
MPP trackers 3 2 1 tracker more
MPPT voltage range 80-550 V 160-1000 V 80-550 V vs 160-1000 V
Weight 17.5 kg 18.0 kg 0.5 kg lighter
Strings per tracker 1 2 1 string apart
Dimensions 380x468x187 mm 480x370x195 mm 380x468x187 mm vs 480x370x195 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SOFAR 7KTLM-G3 SG5.0RT Difference
AC output
Rated AC power 7.00 kW 7.00 kW Same
Max AC power 7.00 kW 7.70 kW 0.70 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 35.0 A 11.7 A 23.3 A apart
PV input
Max PV power - 10.50 kW Not published by Sofar Solar
DC/AC ratio - 1.50 Not published by Sofar Solar
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 80-550 V 160-1000 V 80-550 V vs 160-1000 V
Start voltage 90 V 180 V -90 V for SOFAR 7KTLM-G3
MPP trackers 3 2 +1 trackers for SOFAR 7KTLM-G3
Strings per tracker 1 2 1 string apart
Max input current per tracker 20.0 A 25.0 A +5.0 A for SG5.0RT
Efficiency
European efficiency 97.3 % 97.7 % +0.4 pp for SG5.0RT
Max efficiency 98.1 % 98.4 % +0.3 pp for SG5.0RT
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 17.5 kg 18.0 kg -0.5 kg for SOFAR 7KTLM-G3
Weight per kW 2.5 kg/kW 2.6 kg/kW Effectively the same
Dimensions 380x468x187 mm 480x370x195 mm 380x468x187 mm vs 480x370x195 mm
Ingress protection IP65 IP65 Same
Cooling natural forced-air natural vs forced-air
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Sofar Solar
Arc fault protection - Yes Not published by Sofar Solar
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
SOFAR 7KTLM-G3 vs Growatt MOD 7000TL3-X
14 differences, the largest is european efficiency
Same type, similar size
Growatt
SOFAR 7KTLM-G3 vs Growatt MOD 7KTL3-X2(Pro)
13 differences, the largest is european efficiency
Same type, similar size
Sungrow
SOFAR 7KTLM-G3 vs Sungrow SG7.0RT-P2
12 differences, the largest is max dc voltage
Same type, similar size
Deye
Sungrow SG5.0RT vs Deye SUN-7K-G03
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.