Skip to main content
SOFAR 45KTLX-G3 vs MID 40KTL3-X 10 of 20 identical Swap Change inverters

SOFAR 45KTLX-G3 vs Growatt MID 40KTL3-X

SOFAR 45KTLX-G3
Sofar Solar
SOFAR 45KTLX-G3
45 kW 98.2 % euro Grid-tie
VS
Growatt MID 40KTL3-X
Growatt
MID 40KTL3-X
40 kW 98.5 % euro Grid-tie
The verdict

10 differences, and they point both ways

The largest is rated ac power: 5.00 kW apart. 10 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
10 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 20 parameters
Parameter SOFAR 45KTLX-G3 MID 40KTL3-X Difference
Rated AC power 45.00 kW 40.00 kW 5.00 kW apart
Max input current per tracker 40.0 A 26.0 A 14.0 A more headroom
Max AC power 50.00 kW 44.00 kW 6.00 kW apart
Weight 37.0 kg 30.5 kg 6.5 kg lighter
European efficiency 98.2 % 98.5 % 0.3 pp more efficient
Max AC current 75.8 A 66.6 A 9.2 A apart
Start voltage 200 V 250 V 50 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 180-1000 V 200-1000 V 180-1000 V vs 200-1000 V
Dimensions 480x585x220 mm 435x580x230 mm 480x585x220 mm vs 435x580x230 mm
02

Full specification

Parameter SOFAR 45KTLX-G3 MID 40KTL3-X Difference
AC output
Rated AC power 45.00 kW 40.00 kW 5.00 kW apart
Max AC power 50.00 kW 44.00 kW 6.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 75.8 A 66.6 A 9.2 A apart
PV input
Max PV power - 60.00 kW Not published by Sofar Solar
DC/AC ratio - 1.50 Not published by Sofar Solar
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 180-1000 V 200-1000 V 180-1000 V vs 200-1000 V
Start voltage 200 V 250 V -50 V for SOFAR 45KTLX-G3
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 26.0 A +14.0 A for SOFAR 45KTLX-G3
Efficiency
European efficiency 98.2 % 98.5 % +0.3 pp for MID 40KTL3-X
Max efficiency 98.8 % 98.8 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 37.0 kg 30.5 kg -6.5 kg for MID 40KTL3-X
Weight per kW 0.8 kg/kW 0.8 kg/kW Same
Dimensions 480x585x220 mm 435x580x230 mm 480x585x220 mm vs 435x580x230 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Sofar Solar
Arc fault protection - Yes Not published by Sofar Solar
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Sofar Solar
03

More useful comparisons

Open all inverters
Same type, similar size
Deye
SOFAR 45KTLX-G3 vs Deye SUN-45K-G-LV
11 differences, the largest is max dc voltage
Same type, similar size
Deye
SOFAR 45KTLX-G3 vs Deye SUN-45K-G03
9 differences, the largest is max dc voltage
Same type, similar size
Huawei
SOFAR 45KTLX-G3 vs Huawei SUN2000-50KTL-JPM0
10 differences, the largest is rated ac power
Same type, similar size
Huawei
Growatt MID 40KTL3-X vs Huawei SUN2000-40KTL-M3
7 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Growatt MID 40KTL3-X vs Solis-40K
7 differences, the largest is max pv power
Same type, similar size
Sungrow
Growatt MID 40KTL3-X vs Sungrow SG40CX-P2
10 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.