SOFAR 40KTLX-G3 vs Sungrow SG40CX-P2
VS
The verdict
SOFAR 40KTLX-G3 leads on the differences that matter
The largest is max input current per tracker: 10.0 A more headroom. 14 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
14
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 20 parameters
What actually differs
Parameter
SOFAR 40KTLX-G3
SG40CX-P2
Difference
Max input current per tracker
40.0 A
30.0 A
10.0 A more headroom
Weight
37.0 kg
40.0 kg
3.0 kg lighter
Max efficiency
98.8 %
98.5 %
0.3 pp more efficient
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
180-1000 V
160-1000 V
180-1000 V vs 160-1000 V
Dimensions
480x585x220 mm
575x645x245 mm
480x585x220 mm vs 575x645x245 mm
02
Full specification
Parameter
SOFAR 40KTLX-G3
SG40CX-P2
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
44.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
66.7 A
66.9 A
Effectively the same
PV input
Max PV power
-
56.00 kW
Not published by Sofar Solar
DC/AC ratio
-
1.40
Not published by Sofar Solar
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
160-1000 V
180-1000 V vs 160-1000 V
Start voltage
200 V
200 V
Same
MPP trackers
-
4
Not published by Sofar Solar
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
30.0 A
+10.0 A for SOFAR 40KTLX-G3
Efficiency
European efficiency
98.2 %
98.3 %
Effectively the same
Max efficiency
98.8 %
98.5 %
+0.3 pp for SOFAR 40KTLX-G3
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
37.0 kg
40.0 kg
-3.0 kg for SOFAR 40KTLX-G3
Weight per kW
0.9 kg/kW
1.0 kg/kW
Effectively the same
Dimensions
480x585x220 mm
575x645x245 mm
480x585x220 mm vs 575x645x245 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Sofar Solar
Arc fault protection
-
Yes
Not published by Sofar Solar
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SOFAR 40KTLX-G3 vs Growatt MID 40KTL3-X
7 differences, the largest is max input current per tracker
Same type, similar size
Huawei
SOFAR 40KTLX-G3 vs Huawei SUN2000-40KTL-M3
9 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
SOFAR 40KTLX-G3 vs Solis-40K
5 differences, the largest is weight
Same type, similar size
Sungrow
Sungrow SG40CX-P2 vs Sungrow SG40CX
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.