Skip to main content
SOFAR 350KTLX0 vs S6-GU350K-EHV-M12 11 of 18 identical Swap Change inverters

SOFAR 350KTLX0 vs Ginlong Solis S6-GU350K-EHV-M12

SOFAR 350KTLX0
Sofar Solar
SOFAR 350KTLX0
350 kW 98.8 % euro Grid-tie
VS
Ginlong Solis S6-GU350K-EHV-M12
Ginlong Solis
S6-GU350K-EHV-M12
350 kW 98.7 % euro Grid-tie
The verdict

SOFAR 350KTLX0 leads on the differences that matter

The largest is max ac power: 2.00 kW apart. 11 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
11 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 18 parameters
Parameter SOFAR 350KTLX0 S6-GU350K-EHV-M12 Difference
Max AC power 352.00 kW 350.00 kW 2.00 kW apart
Weight 113.0 kg 134.0 kg 21.0 kg lighter
Start voltage 550 V 500 V 50 V earlier start
Max AC current 254.1 A 252.6 A 1.5 A apart
MPPT voltage range 500-1500 V 480-1500 V 500-1500 V vs 480-1500 V
Strings per tracker 4 2 2 strings apart
Dimensions 828x1159x366 mm 954x1186x467 mm 828x1159x366 mm vs 954x1186x467 mm
02

Full specification

Parameter SOFAR 350KTLX0 S6-GU350K-EHV-M12 Difference
AC output
Rated AC power 350.00 kW 350.00 kW Same
Max AC power 352.00 kW 350.00 kW 2.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 800 V 800 V Same
Max AC current 254.1 A 252.6 A 1.5 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1500 V 1500 V Same
MPPT voltage range 500-1500 V 480-1500 V 500-1500 V vs 480-1500 V
Start voltage 550 V 500 V -50 V for S6-GU350K-EHV-M12
MPP trackers - - Neither datasheet publishes this
Strings per tracker 4 2 2 strings apart
Max input current per tracker 60.0 A - Not published by Ginlong Solis
Efficiency
European efficiency 98.8 % 98.7 % Effectively the same
Max efficiency 99.0 % 99.0 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 113.0 kg 134.0 kg -21.0 kg for SOFAR 350KTLX0
Weight per kW 0.3 kg/kW 0.4 kg/kW Effectively the same
Dimensions 828x1159x366 mm 954x1186x467 mm 828x1159x366 mm vs 954x1186x467 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Sungrow
SOFAR 350KTLX0 vs Sungrow SG350HX
4 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
SOFAR 350KTLX0 vs Ginlong Solis S6-GU350K-EHV-M16
7 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
SOFAR 350KTLX0 vs Ginlong Solis S6-GU3P350K06-EV-ND
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.