SOFAR 255KTL-HV vs Growatt MAX 253KTL3-X HV
VS
The verdict
SOFAR 255KTL-HV leads on the differences that matter
The largest is rated ac power: 2.00 kW apart. 12 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
12
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 19 parameters
What actually differs
Parameter
SOFAR 255KTL-HV
MAX 253KTL3-X HV
Difference
Rated AC power
255.00 kW
253.00 kW
2.00 kW apart
Max AC power
255.00 kW
253.00 kW
2.00 kW apart
Weight
99.0 kg
109.0 kg
10.0 kg lighter
European efficiency
98.7 %
98.5 %
0.2 pp more efficient
Start voltage
550 V
500 V
50 V earlier start
Max AC current
184.0 A
182.6 A
1.4 A apart
Dimensions
714x1100x368 mm
675x1070x340 mm
714x1100x368 mm vs 675x1070x340 mm
02
Full specification
Parameter
SOFAR 255KTL-HV
MAX 253KTL3-X HV
Difference
AC output
Rated AC power
255.00 kW
253.00 kW
2.00 kW apart
Max AC power
255.00 kW
253.00 kW
2.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
800 V
800 V
Same
Max AC current
184.0 A
182.6 A
1.4 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1500 V
1500 V
Same
MPPT voltage range
500-1500 V
500-1500 V
Same
Start voltage
550 V
500 V
-50 V for MAX 253KTL3-X HV
MPP trackers
12
-
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
30.0 A
30.0 A
Same
Efficiency
European efficiency
98.7 %
98.5 %
+0.2 pp for SOFAR 255KTL-HV
Max efficiency
99.0 %
99.0 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
99.0 kg
109.0 kg
-10.0 kg for SOFAR 255KTL-HV
Weight per kW
0.4 kg/kW
0.4 kg/kW
Same
Dimensions
714x1100x368 mm
675x1070x340 mm
714x1100x368 mm vs 675x1070x340 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Sofar Solar
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Sofar Solar
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
SOFAR 255KTL-HV vs Solis-255K-EHV-5G-PLUS
4 differences, the largest is weight
Same type, similar size
Sofar Solar
SOFAR 255KTL-HV vs SOFAR 250KTLX0
7 differences, the largest is rated ac power
Same type, similar size
Sungrow
SOFAR 255KTL-HV vs Sungrow SG250HX-20
8 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.