Skip to main content
SOFAR 250KTLX0 vs Solis-255K-EHV-5G-PLUS 10 of 19 identical Swap Change inverters

SOFAR 250KTLX0 vs Solis-255K-EHV-5G-PLUS

SOFAR 250KTLX0
Sofar Solar
SOFAR 250KTLX0
250 kW 98.8 % euro Grid-tie
VS
Solis-255K-EHV-5G-PLUS
Ginlong Solis
Solis-255K-EHV-5G-PLUS
255 kW 98.8 % euro Grid-tie
The verdict

SOFAR 250KTLX0 leads on the differences that matter

The largest is rated ac power: 5.00 kW apart. 10 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
10 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 19 parameters
Parameter SOFAR 250KTLX0 Solis-255K-EHV-5G-PLUS Difference
Rated AC power 250.00 kW 255.00 kW 5.00 kW apart
Max input current per tracker 60.0 A 30.0 A 30.0 A more headroom
Max AC power 250.00 kW 255.00 kW 5.00 kW apart
Weight 111.0 kg 113.0 kg 2.0 kg lighter
Max AC current 180.5 A 184.0 A 3.5 A apart
Start voltage 550 V 500 V 50 V earlier start
MPPT voltage range 500-1500 V 480-1500 V 500-1500 V vs 480-1500 V
Strings per tracker 4 2 2 strings apart
Dimensions 828x1159x366 mm 770x1125x384 mm 828x1159x366 mm vs 770x1125x384 mm
02

Full specification

Parameter SOFAR 250KTLX0 Solis-255K-EHV-5G-PLUS Difference
AC output
Rated AC power 250.00 kW 255.00 kW 5.00 kW apart
Max AC power 250.00 kW 255.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 800 V 800 V Same
Max AC current 180.5 A 184.0 A 3.5 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1500 V 1500 V Same
MPPT voltage range 500-1500 V 480-1500 V 500-1500 V vs 480-1500 V
Start voltage 550 V 500 V -50 V for Solis-255K-EHV-5G-PLUS
MPP trackers - 12 Not published by Sofar Solar
Strings per tracker 4 2 2 strings apart
Max input current per tracker 60.0 A 30.0 A +30.0 A for SOFAR 250KTLX0
Efficiency
European efficiency 98.8 % 98.8 % Same
Max efficiency 99.0 % 99.0 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 111.0 kg 113.0 kg -2.0 kg for SOFAR 250KTLX0
Weight per kW 0.4 kg/kW 0.4 kg/kW Same
Dimensions 828x1159x366 mm 770x1125x384 mm 828x1159x366 mm vs 770x1125x384 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Sungrow
SOFAR 250KTLX0 vs Sungrow SG250HX-20
4 differences, the largest is max input current per tracker
Same type, similar size
Growatt
SOFAR 250KTLX0 vs Growatt MAX 250KTL3-X HV
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
SOFAR 250KTLX0 vs Growatt MAX 253KTL3-X HV
9 differences, the largest is rated ac power
Same type, similar size
Sofar Solar
Solis-255K-EHV-5G-PLUS vs SOFAR 255KTL-HV
4 differences, the largest is weight
04

Written summary

Checking cache...