SOFAR 125KTLX-G4-A vs Huawei SUN2000-125KTL-NHM0
VS
The verdict
SOFAR 125KTLX-G4-A leads on the differences that matter
The largest is mpp trackers: 9 trackers more. 9 of 12 comparable parameters are identical, with 20 more left out because at least one datasheet does not publish them.
See all 3 differencesHow alike are they
9
of 12 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
3 of 12 parameters
What actually differs
Parameter
SOFAR 125KTLX-G4-A
SUN2000-125KTL-NHM0
Difference
MPP trackers
10
1
9 trackers more
Weight
75.0 kg
99.0 kg
24.0 kg lighter
Dimensions
695x970x325 mm
820x925x365 mm
695x970x325 mm vs 820x925x365 mm
02
Full specification
Parameter
SOFAR 125KTLX-G4-A
SUN2000-125KTL-NHM0
Difference
AC output
Rated AC power
125.00 kW
125.00 kW
Same
Max AC power
125.00 kW
125.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
-
Not published by Huawei
Max AC current
190.0 A
-
Not published by Huawei
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
-
Not published by Huawei
MPPT voltage range
180-1000 V
-
Not published by Huawei
Start voltage
200 V
-
Not published by Huawei
MPP trackers
10
1
+9 trackers for SOFAR 125KTLX-G4-A
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
-
Not published by Huawei
Efficiency
European efficiency
98.3 %
-
Not published by Huawei
Max efficiency
98.6 %
98.6 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
75.0 kg
99.0 kg
-24.0 kg for SOFAR 125KTLX-G4-A
Weight per kW
0.6 kg/kW
0.8 kg/kW
Effectively the same
Dimensions
695x970x325 mm
820x925x365 mm
695x970x325 mm vs 820x925x365 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Huawei
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Huawei
Integrated DC switch
Yes
-
Not published by Huawei
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
SOFAR 125KTLX-G4-A vs Ginlong Solis S5-GC125K-HV
7 differences, the largest is max input current per tracker
Same type, similar size
Growatt
SOFAR 125KTLX-G4-A vs Growatt MAX 125KTL3-X LV
4 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
SOFAR 125KTLX-G4-A vs Sungrow SG125CX-P2
5 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.